[SNMP Generic trap] - [linkUP] - [On/Off]
When the check box is checked, a trap (SNMPv2-MIB:: linkup) will be sent at the time when the camera is
linked up.
•
Default:
Not checked (Off)
[SNMP Generic trap] - [linkUP] - [Trap string]
When a camera linkup trap is to be extended and sent, set the string of characters of the extended trap.
•
Available number of characters:
0 - 20 characters
•
Available characters:
0-9, A-Z, a-z and the following marks.
! " # $ % & ' ( ) * + , - . / : ; = ?
•
Default:
linkup
[SNMP Generic trap] - [authenticationFailure] - [On/Off]
When the check box is checked, a trap (SNMPv2-MIB::coldStart) will be sent at the time when an SNMP
authentication error occurs.
•
Default:
Not checked (Off)
[SNMP Generic trap] - [authenticationFailure] - [Trap string]
When a SNMP authentication error occurrence trap is to be extended and sent, set the string of characters.
•
Available number of characters:
0 - 20 characters
•
Available characters:
0-9, A-Z, a-z and the following marks.
! " # $ % & ' ( ) * + , - . / : ; = ?
•
Default:
auth error
[Alarm] - [VMD] - [On/Off]
When the check box is checked, a trap will be sent at the time when a video motion detection is activated.
•
Default:
Not checked (Off)
[Alarm] - [VMD] - [Trap string]
Set the string of characters to be used for the trap of [VMD].
•
Available number of characters:
0 - 20 characters
•
Available characters:
0-9, A-Z, a-z and the following marks.
! " # $ % & ' ( ) * + , - . / : ; = ?
•
Default:
VMD alarm
[Alarm] - [Audio detection] - [On/Off]
When the check box is checked, a trap will be sent at the time when an audio detection alarm occurs.
•
Default:
Not checked (Off)
[Alarm] - [Audio detection] - [Trap string]
Set the string of characters to be used for the trap of [Audio detection].
•
Available number of characters:
0 - 20 characters
•
Available characters:
0-9, A-Z, a-z and the following marks.
! " # $ % & ' ( ) * + , - . / : ; = ?
•
Default:
audio
[Alarm] - [Command alarm] - [On/Off]
When the check box is checked, a trap will be sent at the time when a command alarm occurs.
•
Default:
Not checked (Off)
[Alarm] - [Command alarm] - [Trap string]
Set the string of characters to be used for the trap of [Command alarm].
•
Available number of characters:
0 - 20 characters
Operating Instructions
147
3 Detailed Settings