background image

 

Analox Limited 

15 Ellerbeck Court, Stokesley Business Park, 

North Yorkshire, TS9 5PT, UK 

T: +44 (0)1642 711400 F: +44 (0)1642 713900 

W: www.analox.net E: [email protected] 

 

Ax60 Carbon 

Dioxide Detector 

Quick Start Guide - Hard 

Wired Option 

 

Содержание Ax60

Страница 1: ...ited 15 Ellerbeck Court Stokesley Business Park North Yorkshire TS9 5PT UK T 44 0 1642 711400 F 44 0 1642 713900 W www analox net E info analox net Ax60 Carbon Dioxide Detector Quick Start Guide Hard Wired Option ...

Страница 2: ...NDER WITH A SOUND LEVEL OF 88 DECIBELS AT A DISTANCE OF 3 METRES WARNING DO NOT TEST THE CO2 ALARM WHEN IT IS CLOSE TO THE EYES IT HAS A HIGH VISIBILITY STROBE LIGHT WITH A LUMINOUS INTENSITY OF 100 CANDELA WARNING ENSURE YOU PERFORM A RISK ASSESSMENT BEFORE INSTALLING CO2 SENSORS AND CO2 ALARMS IDENTIFY POTENTIAL SOURCES OF CO2 LEAKS AND AREAS OF HUMAN OCCUPATION DO NOT USE A SINGLE CO2 SENSOR TO...

Страница 3: ...n Dioxide Detector Quick Start Guide Hard Wired Option Document ref P0159 802 03 September 2015 Page 3 of 16 Contents 1 Introduction 4 2 Installation 6 3 Cabling 7 4 Connection 8 5 Operation 12 6 Configuration 16 ...

Страница 4: ...nsors and CO2 Alarms that are connected to it An Ax60 Central Display can be connected to a maximum of four CO2 Sensors and a maximum of eight CO2 Alarms To extend the alarm functions an optional beacon is available and two alarm relay outputs are provided for integration with other systems The Central Display is usually installed in a principal location e g a Manager s office and connected to one...

Страница 5: ...the package ordered 1 x high visibility optional beacon if ordered Self adhesive foam gaskets for use in rear entry cable installations 1 x hazard labels information labels templates and Quick Start Guide Consumables depending on the package Cat5e UTP 24AWG PVC cable length to suit installation M13 cable glands 5 7mm nylon quantity to suit installation Wall plugs and screws fixing kits quantity to...

Страница 6: ...ace the enclosure face down on a solid non slip surface Tap the knockout firmly using a hammer and punch Use pliers to remove sharp edges from the aperture 2 1 2 CO2 Sensor Retain the clear protective film on the fascia until the installation is complete Using the supplied paper template mark out the wall fixing position ensuring the CO2 Sensor is level If installing a cable through the rear remov...

Страница 7: ...Cable type Wire colour Abbreviation Cat5e UTP Orange ORG 24AWG PVC Orange white ORG WHT Brown BRN Brown white BRN WHT Green white GRN WHT Green GRN Blue white BLU WHT Blue BLU If you install cables through walls remove the knockout and fit a foam gasket to maintain ingress protection see below left If you install cables along wall surfaces fit cable glands below right CAUTION ENSURE THAT THE MAXIM...

Страница 8: ...ow For the purposes of this example the enclosures have been removed and the cables have been shortened for convenience The Central Display is not shown 1 Two CO2 Sensors connected together in a daisy chain 2 Two CO2 Alarms connected together in a daisy chain 4 2 Central Display CO2 Sensor Beacon Power Relay 2 Relay 1 See section 4 2 1 See section 4 2 3 See section 4 2 2 NOTE REFER TO THE Ax60 SER...

Страница 9: ... supplied with plug for specific country PSU hard wired type for connection to a fixed power supply The plug in PSU is supplied with a securing strip wall plugs and screws to reduce risk of accidental disconnection or tampering WARNING THE POSITIVE AND NEGATIVE POWER CABLES ARE IDENTIFIED DIFFERENTLY DEPENDING ON THE TYPE OF PSU SUPPLIED READ THE INSTRUCTIONS BELOW BEFORE INSTALLING THE PSU CABLE ...

Страница 10: ... BE REMOVED CUT OFF NOTE SENSOR 2 CABLE SHOULD BE DAISY CHAINED FROM SENSOR 1 TERMINALS 4 3 2 CO2 Sensor to CO2 Alarm Cable connections from top to bottom ORG ORG WHT supply positive two cables twisted together BRN BRN WHT supply negative two cables twisted together GRN WHT alarm strobe driver single cable GRN alarm sounder driver single cable BLU WHT fault LED driver single cable NOTE THE BLUE CA...

Страница 11: ...river single cable BRN BRN WHT supply negative two cables twisted together ORG ORG WHT supply positive two cables twisted together NOTE THE BLUE CABLE CAN BE REMOVED CUT OFF 4 5 Optional beacon CAUTION ENSURE THE TERMINAL BLOCK ON THE UNDERSIDE OF THE BEACON IS FITTED TO THE 0V AND THE 24V PINS THEN ENSURE THAT THE POWER CABLES ARE CONNECTED TO THE 0V AND THE 24V SCREW TERMINALS Black cable 0V sup...

Страница 12: ...L1 or CO2 and rapid operation of the buzzer Buzzer apertu re on the left of the indicators Buzzer sounds briefly each time a button is pressed Sounds continuously for five seconds when using the TESTING ALARMS function It sounds rapidly on and off when an alarm is triggered or once per second for a fault 5 1 2 Control buttons Cancel To use this button press it firmly then release it quickly The bu...

Страница 13: ...ODE If a CO2 Sensor is in fault any CO2 Alarms connected to it will also display a fault status their yellow Fault indicator LEDs will flash NOTE FAULT CODES ARE DESCRIBED IN DETAIL IN THE SERVICE MANUAL 5 3 CO2 Alarm The CO2 Alarm has a green Power indicator and a yellow Fault indicator on the bottom part of the fascia These are used to indicate the following conditions Power indicator Under norm...

Страница 14: ...Vendor name may vary No further operator input is required The power on self test is an automatic process Performs a checksum configuration check Performs a software validation check Checks the CO2 Sensor s have been calibrated This displays if no sensors have been configured Confirms top line of LCD OK no pixels are missing Confirms bottom line of LCD OK no pixels missing Confirms buzzer is off a...

Страница 15: ... For example a system with two CO2 Sensors displays OK OK The character identifies which CO2 Sensor is highlighted CO2 Sensor 1 is highlighted by default The CO2 concentration is by default displayed in ppm parts per million The example shown here displays 450 PPM which is equal to 0 045 NOTE THE SYSTEM STATUS SCREEN DISPLAYS UP TO 4 CO2 SENSORS A SPARE CO2 SENSOR LOCATION DISPLAYS AS The bottom l...

Страница 16: ...k in LOCATION 2 and the third Sensor s link should be in LOCATION 3 For a system with four CO2 Sensors the first Sensor s jumper link should be in LOCATION 1 the second Sensor s link in LOCATION 2 the third Sensor s link in LOCATION 3 and the fourth Sensor s link should be in LOCATION 4 6 2 Software setting The Central Display software is factory configured for a system that has two Sensors If the...

Отзывы: