Software prerequisites
ServiceNow version Kingston, London
Setup prerequisites
Register the ServiceNow Web Service Connection in Automation Director.
Default ports
Port number
Use
443
Secure communication from Automation Director to ServiceNow.
Edit Service settings
The following table lists the Edit Service settings for the Call ServiceNow Table API service template.
Navigation pane
Settings pane
Description
ServiceNow
ServiceNow Connection Name
Specify the ServiceNow
connection name registered in
the Web Service Connection.
This setting is required.
Table Name
Specify the table name to
execute the API.
This setting is required.
HTTP Method
Specify the method, which is
POST, PUT, or GET.
This setting is required.
sys_id
Specify the system ID (sys_id).
Query Parameters
Specify the query parameter in a
form concatenated with an
encoded character string.
Request Body
Specify the request body in
JSON format.
Submit Service settings
The following table lists the submit Service settings for the Call ServiceNow Table API service template.
186
Services catalog