Removal and Replacement Procedures
2-74
HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide
Re-entering the Server Serial Number
After replacing the system tray or clearing the NVRAM, the server serial number must be re-
entered. To re-enter the serial number:
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select
the
System Options menu.
3. Select
Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press
the
Escape key to close the menu.
6. Press
the
Escape key to exit RBSU.
7. Press
the
F10 key to confirm exiting RBSU. The server will automatically reboot.
Содержание ProLiant ML570 Generation 2
Страница 6: ......