![background image](http://html.mh-extra.com/html/hp/proliant-ml570-generation-2/proliant-ml570-generation-2_maintenance-and-service-manual_164885128.webp)
Troubleshooting
Problems After Initial Boot
Once the server has passed POST, you may still encounter errors, such as an inability to load
the operating system. Use the Table 5-7 to troubleshoot server installation problems that
occur after the initial boot.
Refer to the HP Servers Troubleshooting Guide for more information.
Table 5-7: Problems After Initial Boot
Problem Possible
Reasons Possible
Solutions
SmartStart requirement not
performed.
Check the SmartStart Release Notes
provided in the SmartStart Online
Reference Information on the
SmartStart CD.
IDE cable or power cable
not connected to
CD-ROM drive.
Check the IDE signal cable between
the system board and CD-ROM to
ensure proper connection.
Check the power supply connection
between the CD-ROM drive and the
power backplane.
Insufficient memory is
available.
A rare “insufficient memory” message
may display the
first
time SmartStart
is booted on certain unconfigured
systems. Cold-boot the machine with
the SmartStart CD inserted in the CD-
ROM drive to correct the problem.
System cannot load
SmartStart.
Existing software is causing
conflict.
Run the HP System Erase Utility.
Read the
Caution at the end of this
table. Refer to the instructions in the
HP Servers Troubleshooting Guide
.
continued
5-8
HP ProLiant ML570 Generation 2 Server Maintenance and Service Guide
Содержание ProLiant ML570 Generation 2
Страница 6: ......