Removal and Replacement Procedures
Hot-Plug Procedures
You can perform removal/replacement procedures for some server components without
powering down the server. The following removal/replacement procedures are hot-plug
capable:
•
•
•
•
•
•
•
Power supplies
Processor and I/O fans
Drive fans
Front and rear processor air baffles
SCSI hard drives
PCI and PCI-X Hot Plug expansion boards (in hot-plug slots)
Memory (refer to the “Memory” section in this chapter)
Hot-Plug Power Supplies
CAUTION:
Do not hot-remove a power supply without a redundant power supply in place.
CAUTION:
Hot-plug power supplies for the ProLiant ML570 Generation 2 server are keyed to
make sure that only 600-W hot-plug power supplies can be installed in the server. The
handles on 600-W power supplies are carbon (black) to distinguish them from other power
supplies, which are opal (white).
To remove a hot-plug power supply:
1. Release the AC power cord from the tie wrap on the power supply.
2. Unplug the AC power cord from the power supply.