Hardware options installation 80
Redundant power supply option
Install the RPS backplane option to improve power efficiency and enable power redundancy. Power
redundancy requires the installation of two power input modules. This module is not part of the RPS
backplane option kit.
When this RPS backplane and a single power input module are installed in the server, you can install or
remove a second power input module without powering down the server.
To install the component:
1.
Power down the server (on page
17
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).
o
Remove the server from the rack (on page
20
).
4.
Remove the access panel (on page
21
).
5.
Prepare the server for removal of the existing power supply:
a.
Remove all server components that block access to the power supply cables and screws.
b.
Disconnect all server cables that block access to the power supply cables and screws.
c.
Disconnect all power supply cables from the system board and drive cage.
6.
Remove the existing power supply.
7.
Remove all other components specifically associated with the removed power supply.
8.
Install the RPS backplane:
Содержание ProLiant DL160 Gen9
Страница 92: ...Cabling 92 M 2 SSD cabling Slot 1 cable routing Slot 2 cable routing ...
Страница 94: ...Cabling 94 FBWC module slot 2 cabling FBWC module slot 3 cabling ...
Страница 95: ...Cabling 95 HP Smart Storage Battery cabling FlexibleLOM cabling ...
Страница 98: ...Cabling 98 Front I O cabling Front I O cabling in LFF configuration Front I O cabling in SFF configuration ...
Страница 99: ...Cabling 99 Front USB 3 0 cabling ...
Страница 129: ...Support and other resources 129 ...
Страница 130: ...Support and other resources 130 ...