Hardware options installation 67
a.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
b.
Finish the installation by completely tightening the screws in the same sequence.
13.
Note these population guidelines for installing fans in a dual-processor configuration.
Configuration
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 Fan bay 7
One processor,
non-redundant
Blank
Blank
Blank
Fan
Blank
Fan
Fan
One processor,
redundant
Blank
Blank
Blank
Fan
Fan
Fan
Fan
Two processors,
non-redundant
Fan
Fan
Fan
Blank
Fan
Fan
Fan
Two processors,
redundant
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Содержание ProLiant DL160 Gen9
Страница 92: ...Cabling 92 M 2 SSD cabling Slot 1 cable routing Slot 2 cable routing ...
Страница 94: ...Cabling 94 FBWC module slot 2 cabling FBWC module slot 3 cabling ...
Страница 95: ...Cabling 95 HP Smart Storage Battery cabling FlexibleLOM cabling ...
Страница 98: ...Cabling 98 Front I O cabling Front I O cabling in LFF configuration Front I O cabling in SFF configuration ...
Страница 99: ...Cabling 99 Front USB 3 0 cabling ...
Страница 129: ...Support and other resources 129 ...