Hardware options installation 56
8.
Remove the fan blank.
9.
Install the fan.
CAUTION:
The fan does not have a fan guard. Special attention is needed when removing or
installing the fan to prevent finger injury.
10.
Connect the fan cable to the system board ("
System board components
" on page
12
).
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
11.
Install the access panel (on page
22
).
12.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack ("
Installing the server into the rack
" on page
30
).
13.
Power up the server (on page
17
).