Hardware options installation 54
Fan population guidelines
Configuration
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 Fan bay 7
One processor,
non-redundant
Blank
Blank
Blank
Fan
Blank
Fan
Fan
One processor,
redundant
Blank
Blank
Blank
Fan
Fan
Fan
Fan
Two processors,
non-redundant
Fan
Fan
Fan
Blank
Fan
Fan
Fan
Two processors,
redundant
Fan
Fan
Fan
Fan
Fan
Fan
Fan
•
In a single-processor, nonredundant configuration, fans 4, 6, and 7 cool the server. To enable the
redundant fan mode, install a new fan in the fan bay 5.
•
In a dual-processor, nonredundant configuration, fans 1, 2, 3, 5, 6, and 7 cool the server. To enable
the redundant fan mode, install a new fan in the fan bay 4.
•
In the redundant fan mode:
o
If one fan rotor fails, the system continues to operate without redundancy. This condition is indicated
by a flashing amber Health LED.
o
If two fan rotors fail, the system shuts down.
•
The minimum fan requirement to make this server bootable is three fans for a single processor and six
fans for a dual processor configuration.
Installing a hot-swap fan module
Содержание ProLiant DL160 Gen9
Страница 92: ...Cabling 92 M 2 SSD cabling Slot 1 cable routing Slot 2 cable routing ...
Страница 94: ...Cabling 94 FBWC module slot 2 cabling FBWC module slot 3 cabling ...
Страница 95: ...Cabling 95 HP Smart Storage Battery cabling FlexibleLOM cabling ...
Страница 98: ...Cabling 98 Front I O cabling Front I O cabling in LFF configuration Front I O cabling in SFF configuration ...
Страница 99: ...Cabling 99 Front USB 3 0 cabling ...
Страница 129: ...Support and other resources 129 ...
Страница 130: ...Support and other resources 130 ...