At the end of their useful life, the packaging,
product and batteries should be disposed of
via a suitable recycling centre and in
accordance with national or local legislation.
Technical data
S4-34410
S4 1- Input
S4-34450
S4 4-Input /Output
S4-34420
S4 1-Output & 1-Input
Approval
EN54-17:2005 and EN54-18:2005 (Approval pending)
Weight-dimen. module
module in plastic box
module in metal box
92g
j
1047g
k
782g
100g
j
1055g
k
790g
100g
j
1055g
k
790g
Storage temperature
-30ºC to 70ºC
Operating temperature
-10ºC to 60ºC
Relative Humidity
Up to 95% - Temperature 5ºC to 45°C (Non condensing)
Emission
BS EN 61000-6-3:2001 Residential, Commercial & Light Industry
Class B limits
Immunity
BS EN50130-4: 1996: Part 4
LVD
BS EN 60950-2002
Ingress Protection
IP31 for plastic box S4-34490 & IP40 estimated for metal box S4-34492
Colour
Module-white / Plastic box-dark grey (Lid-light grey) / Metal box-dark grey
Input mode
Input channel-1 only can be configured as a
zone input to accept conventional devices, with
a load of 2mA quiescent and 9mA alarm
maximum at 24V nominal (18V minimum). With
configurable 2s to 5s reset period and 5s to 40s
alarm validation delay.
Switch input can work
with or without a delay.
Input channel can be configured as a
switch input
of Fire*, Fault*, Supervisory*
(non fire) or Confirmation# signal.
* with input acceptance delay of up to 10
seconds for a Fire input and up to 300s for Fault or Supervisory input. # A fault is
generated if confirmation input is not seen within predefined period of the output
action (Confirmation function is not a feature of the single input module).
Output mode
-
A relay output of either NO or
NC set of contacts rated 1A -
30Vac/dc resistive load.
A relay output of change over
contacts NC, COM and NO rated
1A - 30Vac/dc resistive load.
LED output
1.5mA at 24Vdc (Normally On or Normally Off)
Load Factor
1-4 switch inputs =
1
(maximum 200 per loop)
1-4 relay outputs =
2
(maximum 200 per loop only 8 individually sectored)
Zone Input =
26
(maximum 30 per loop)
Every LED output =
+5
(maximum 100 LED outputs per loop)
EN54-17 data
V
max
V
nom
V
min
VSO max
V
SO min
I
C max
I
S max
I
L max
ZC
max
42V
40V
24V
14V
10V
0.4A
1A
20µA
0.1O
W
Panel compatibility
Compatible with LPC = V3.92 / V4.33 & MCC = V3.90 / V4.31.
Data and Installation
Interfaces (Low voltage)
Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without
obligation to notify any person of such revisions of changes.
Hamilton Industrial Park, Waterside Road, Leicester LE5 1TN, UK
Website: www.gent.co.uk
Telephone: +44 (0) 116 246 2000
Fax (UK): +44 (0)116 246 2300
4
4188-873.02_Pt.1_11/06_S4 LV Interfaces
by Honeywell
Do not dispose of with your normal household waste.
Do not burn.
WEEE Directive:
At the end of their useful life, the packaging,
product and batteries should be
disposed of via a suitable recycling centre.
139mm
93mm
24mm
227mm
245mm
Depth 77mm
Healthy
Fault
Fault
System fault
green
amber
202mm
125mm
Depth 50mm
Metal Box
Plastic Box