This leaflet covers a range of Main Control(ler)
Card (MCC) options for BS version 3/3+ control
panels and terminal nodes. Each MCC is supplied
with a number of chips having part numbers
2211-xxx, see chart overleaf. The appropriate chip
must be fitted to the card before card installation.
Card options:
¨
VIG-MCC-BS-NOD-UPG, 34K-MCC-UPGR,
VIG-MCC-V3+, VIG-MCC-3400 and
VIG-MCC-3500-NODE.
Chip 2211-xxx
¨
Fit the correct chip 2211-xxx in the MCC for the
type of panel or node, see chart overleaf.
Battery connection
The MCC has a battery sleeve that must be
removed before the MCC card is installed into the
backplane.
&
Once the battery sleeve is removed from
the MCC, the card MUST NOT be placed on a metal
surface as this may result in damage to the
components on the card.
Technical data
Overall size
157mm height x 100mm
width
Weight
96g (approximate)
Lithium Battery
CR2032 3V cell.
Replace the battery only
with the same or equivalent
type. Dispose of all used
batteries according to the
manufacturer’s instructions.
Operating
temperature
0
°
C to 45
°
C
Storage temperature
-10
°
C to 55
°
C
Relative humidity
(non condensing)
up to 90%
Backplane
The MCC card must be installed in the correct
location on the appropriate backplane.
4188-860 issue 1_01/06_MCC BS
1
Data and Installation instructions
Main Control Cards
(BS - version 3 / 3+ panels or nodes)
by Honeywell
BATT1
Lithium b side up
Remove sleeve before
installing the card
SW1
USB port for
future use
P2 for future use
P4 to accept a
40-way ribbon
cable from the DKC
MCC card socket fits
into the Backplane slot for (LCC)
Reset
Switch
Part number
2211-xxx
40 WAY
RIBBON
CABLE
20 WAY
RIBBON
CABLE
MAIN CONTROL CARD
(Slot or Card 0)
INPUT OUTPUT CARD
(Slot or Card 15)
RAM (Memory) CARD
(Slot or Card 3)
LOOP PROCESSOR CARD
loop 1
(Slot or Card 1)
LOOP PROCESSOR
CARD
Loop 2 optional
(Slot or Card 2)
NETWORK
CARD
(Slot or Card 13)
SPARE
SLOT
IO CARD
(Slot or
Card 15)
MAIN
CONTROL
CARD
(Slot or Card 0)
P4
P5
P6
P7
AC
AC
E
-
+
IO switch
enable
dongle
Dongle
To DKC
40 way ribbon
cable
20 way ribbon
cable
Main Control card
Input/Output card
Loop Processor card
Space for 3 Loop
Processors
RAM Card (only fitted
in 16 line display panel)
Network card
P1
P4
LCC - P1
IOC- P2
LOOP 1 - P3
LOOP 2 - P4
LOOP 3 - P5
LOOP 4 - P6
P7
P8
NETWORK
Card
(Not used
for 3300)
Loop (3300)
IO
CARD
MAIN
CONTROL
CARD
P4
P5
P6
P7
AC
AC
E
-
+
SPARE
SLOT
32K and Senator 2 Network Interface
backplane
3300 Mk2, 32K and Senator 2
Control panel backplane
3505 Terminal node backplane
Vigilon and 34K Control panel and
Network node backplane
MAIN CONTROL
CARD
3404 & 3300 Mk1 Control panel backplane
MAIN CONTROL
CARD
3408 Control panel backplane
IOC
LOOP PROCESSOR CARDS
RAM
NC
IOC
RAM
NC
3300
3404
LOOP PROCESSOR CARDS
NORMAL