HLP-A100 Series
HLP-A100 Series Operating Manual
-
99
-
C06.26
Function Description
Range
Unit
Default Setting
Terminal AI Filter Time
Constant
0.01~10.00
S
0.01
Function: This reference signal should correspond to max. reference/feedback
value set in C06.25.
C06.23
Function Description
Range
Unit
Default Setting
Terminal AI High Current 0.01~20.00 mA
20.00
Function: Enter the time constant, this is a first-order digital low pass filter
time constant for suppressing electrical noise in analog input AI. A
high time constant value improves dampening but also increases
the time delay through the filter. This parameter can’t be adjusted
while the motor is running.
C06.28
Function Description
Range
Unit
Default Setting
Terminal AI Zero Dead
Band
0.00~20.00
0.00
Function: Set the dead band for terminal AI at zero, see C06.18.
Function: Enter the reference or feedback value corresponding to min
voltage or min current set in C06.20 or C06.22, see drawing in
C06.15.
C06.24
Function Description
Range
Unit
Default
Setting
Terminal AI Low Ref. /
Feedb. Value
-4999.000~4999.000
0.000
Function: Enter the reference or feedback value corresponding to max
voltage or max current set in C06.21 or C06.23.
C06.25
Function Description
Range
Unit
Default
Setting
Terminal AI High Ref./
Feedb. Value
-4999.000~4999.000
50.000