HLP-A100 Series Operating Manual
HLP-A100 Series
-
108
-
C08.33 Function Description
Range
Unit
Default Setting
FC Port Parity
0~3
2
Option: [0] Even parity (1 stop bit);
[1] Odd parity (1 stop bit);
[2] No parity (1 stop bit);
[3] No parity (2 stop bit);
Function: This parameter only effective for MODBUS RTU and FC bus
always has even parity.
C08.35 Function Description
Range
Unit
Default Setting
Min. Response Delay
0.001~0.50
s
0.010
Function: Def ine the minmum delay time f rom receiving a request to
transmitting the respond out.
C08.36
Function Description
Range
Unit
Default Setting
Max. Response Delay 0.010~10.000
s
5.000
Function: Specif y maximum permissible delay time between transmitting
a request and receiving a respond. Exceeding this time delay will
cause word timeout.
C08.50 Function Description
Range
Unit
Default Setting
Coasting Select
0~3
3
Option: [0] Digital input, Activate via a digital input;
[1] Bus, Activate via serial communication port;
[2] Logic and, Activate via serial communication port and a digital
input;
[3] Logic or Activate via serial communication port or a digital input;
Function: Select control of coasting f unction via digital input or bus.
C08.51 Function Description
Range
Unit
Default Setting
Quick Stop Select
0~3
3
Option: [0] Digital input, Aciviate via a digital input;
[1] Bus, Activate via serial communication port;
C08.5* Digital/Bus
This parameter only active only when C08.01 (control site) is set to (0)
digital and control word.