HLP-A100 Series Operating Manual
HLP-A100 Series
-
38
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ram
ete
r G
rou
p
05:
D
igit
al I
n/O
ut
C05.55
Terminal
DI4 Low
Frequency
0.020~49.999
KHz 0.020
91
C05.56
Terminal
DI4 High
Frequency
0.021~50.000
KHz 50.000
91
C05.57
Terminal DI4
Low Ref./
Feedb. Value
-4999.000~4999.000
0.000
91
C05.58
Terminal DI4
High Ref./
Feedb.Value
-4999.000~4999.000
50.000
92
C05.59
Terminal DI4
Filter Time
Constant
1~1000
ms
100
92
C05.60
Terminal DO1
Pulse Output
Variable
0: Dgital output;
10: Output frequency;
11: Reference;
12: Feedback;
13: Motor current;
16: Power; 17: Speed;
18: Motor voltage;
20: Bus control;
21: Pulse input;
22: Terminal VI
input; 23: Terminal
AI input;
0
92
C05.61
Pulse Output
Min Freq
0.020~49.999
KHz 0.020
93
C05.62
Pulse Output
Max Freq
0.021~50.000
KHz 50.000
93
C05.63
Pulse Output
Min Scale
0.00~200.00
%
0.00
93
C05.64
Pulse Output
Max Scale
0.00~200.00
%
100.00
93
C06.00
Live Zero
Timeout Time 1~99
s
10
94