HLP-A100 Series Operating Manual
HLP-A100 Series
-
56
-
Binary
bit0
Set-up No.
Terminal State
0
1
1
2
Attention: The set-up can be switched between linked set-ups (See
C00.12) or when the motor is stop.
C00.11 Function Description Range
Unit
Default Setting
Edit Set-up
1~2
1
Option: [1] Set-up 1;
[2] Set-up 2;
Function: This parameter can be edited via LCP or serial communication
port.
*C00.12 Function Description
Range
Unit
Default Setting
Link Set-ups
1~20
20
Option: [0] not linked, parameters between two set-ups can not change
each other while the motor is running;
[20] Linked, the link ensures synchronizing of the parameters
that can not be changed, while the motor is running. When this
is done, it is possible to shift from one set-up to the active set-up
selected.
Description of the choice: This parameter should be used in conjunction
with the active set-up. When C00.12 = 20, synchronize the “not
changeable during operation” parameters of the two set-ups.
When C00.10 = 9, the motor is running and switching the active
set-up is needed, if C00.12 = 20, switching can be achieved
while the motor is running; if C00.12 =0, set-ups can’t be
switched until the motor is stopped.
C00.31 Function Description
Range
Unit
Default Setting
Custom Readout Min
Value
0~9999.00
0.00
Function: This parameter occurs at 0 Speed.
Description of the choice: This parameter allows the choice of the min.
value of the custom defined readout.
C00.3* LCP Readout