HLP-A100 Series
HLP-A100 Series Operating Manual
-
41
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
C06.93
Terminal AO
Output Min
Scale
0.00~200.00
%
0.00
101
C06.94
Termianl AO
Max Scale
0.00~200.00
%
100.00
102
Pa
ram
ete
r G
rou
p0
7: C
on
trol
ler
s
C07.12
Torque PI
Proportional
Gain
0~500
%
100
C07.13
Torque PI
Integration
Time
0.002~2
S
0.02
C07.20
Process CL
Feedback
Resource
0: No Function;
1: Analog in VI;
2: Analog in AI;
8: Pulse input;
11: Local bus;
0
103
C07.30
Process PI
Normal/
Inverse
Control
0: Normal; 1: Inverse
0
103
C07.31
Process PI
Anti Windup
0: Disabled;
1: Enabled;
1
104
C07.32
Process PI
Start Speed
0.0~200.0
Hz
0.0
104
C07.33
Process PI
Proportional
Gain
0.0~10.00
0.01
105
C07.34
Process PI
Integral time 0.10~9999.00
s
9999.00 105
C07.38
Process PI
Feed Forward
Factor
0~400
%
0
105
C07.39
On Reference
Bandwidth
0~200
%
5
105
C07.41
Process PI
Output Low -100-100
%
0
105
C07.42
Process PI
Output High -100-100
%
100
106