HLP-A100 Series Operating Manual
HLP-A100 Series
-
148
-
C30.20 Function Description
Range
Unit
Default Setting
Random Function Mode
0~1
0
Option: [0] : Disable;
[1] : Enable;
Function: If [0] is selected, wobble up time and wobble down time are not
randomized.
If [1] is selected, the actual wobble up time(Tup) and wobble down
time(Tdown)will be fluctuated by a random value in the way below:
tup = tup + f random * min(tup, tdown ) / 100.
tdown = tdown - f random * min(tup, tdown ) / 100.
Frandom is a random value between maximum randomized wobble
ratio and minimum randomized wobble ratio.
C30.21 Function Description
Range
Unit
Default Setting
Max. Radom Ratio
-20~20
%
10
Function: This parameter determines the maxmum wobble ratio which the
random f unction is allowed to choose.
C30.22 Function Description
Range
Unit
Default Setting
Min. Radom Ratio
-20~20
%
-10
Function: This parameter determines the minimum wobble ratio which the
random f unction is allowed to choose .
C30.2* Wobble Random
C30.30 Function Description
Range
Unit
Default Setting
Wobble Length Source
0~8
0
Option: [0]: Digital input, counter A is used as count source;
[7]: Encoder input, encoder input is used as count source;
[8]: Pulse input, pulse input is used as count source;
Function: This parameter is used to select wobble length source.
C30.31 Function Description
Range
Unit
Default Setting
Count Per Meter
0.01~600.00
1.00
Function: Wobble Length= (Digital input
、
Encoder input or Pulse
input)*Count per meter.
C30.3* Wobble Process Control