14-10
Chapter 14
RS485 Communication
14.3.6
Time required for communication
• The inverter’s response after it receives a query is equal
to [CF-07] (communication waiting time) setting value
plus processing time for creating response.
14.3.7
Responses in the normal condition
• A response is returned in accordance with the format for
each query defined in “3. Description of Each Function
code”.
14.3.8
Responses in the abnormal condition
• When there is a failure (excluding communication error)
in the content of a query, the inverter returns an
exceptional response without executing any action
requested by the query.
• For error determination, check the function code of the
response. The function code of the exceptional response
is the value obtained by adding 80h to the function code
of the query.
14.3.9
No response
• The inverter ignores a query and returns no response in
the following conditions:
(1)
A broadcast (query with slave address “0”) is received.
(2)
A communication error is detected during a query
reception processing.
(3)
The query’s slave address doesn’t match the slave
address set in the inverter.
(4)
The time interval between data constituting a message
is 3.5 characters or less.
(5)
The data of query is in the wrong length.
(6)
The reception interval within frame exceeds 1.5
character.
• When transmitting the next query to the inverter after
receiving a response from the inverter, make sure to
provide an interval equal to the silent interval of [at least
3.5 characters] or more.
• Field composition for
exceptional response
• For more details of errors, see “14.3.9 Exceptional
Responses”.
(7)
An error check code of query does not match (CRC
error).
(8)
A simultaneous broadcasting by group (query with
slave address from 250 to 254) is received.
• Provide the master with a timer for monitoring responses,
then if a response is not returned within the time, transmit
the same query again.
!
Slave address
Function code
Exception code
CRC-16
Содержание SJ Series
Страница 39: ...5 4 Chapter 5 Included Items Memo ...
Страница 52: ...6 13 Chapter 6 Installation Model P1 P1 200V class P1 02950 L P1 550L Dimension W mm H mm D mm 480 700 250 ...
Страница 55: ...6 16 Chapter 6 Installation Memo ...
Страница 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Страница 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Страница 145: ...10 10 Chapter 10 Test Run Memo ...
Страница 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Страница 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Страница 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Страница 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Страница 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Страница 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Страница 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Страница 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Страница 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Страница 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Страница 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Страница 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Страница 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Страница 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Страница 661: ...20 11 Chapter 20 Specifications Model P1 P1 200V class 02950 L 550L Dimension W mm H mm D mm 700 480 250 ...
Страница 662: ...20 12 Chapter 20 Specifications Model P1 P1 400V class 01760 H 750H 02130 H 900H Dimension W mm H mm D mm 390 700 270 ...
Страница 663: ...20 13 Chapter 20 Specifications Model P1 P1 400V class 02520 H 1100H 03160 H 1320H Dimension W mm H mm D mm 480 740 270 ...
Страница 678: ...21 7 Chapter 21 Technical Notes SJ700D SJ P1 ND normal duty SJ700D 550LFF3 P1 02950 LFEF P1 550LFF ...
Страница 686: ...21 15 Chapter 21 Technical Notes SJ700B SJ P1 LD low duty VLD very low duty SJ700B 750LFF P1 02950 LFEF P1 550LFF ...
Страница 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...