n

Lastgeregelter Lokdecoder

für Gleichstrommotoren

Motorola-Format

n

n

Locomotive Decoder

with load control for

DC engines - Motorola format

n

Anleitung

n

Manual

Décodeur avec compensation de

charge pour locomotive avec

moteur continu - Format Motorola

n

Mode d´emploi

n

Handleiding

Lastgeregelde Locdecoder

voor gelijkstroommotoren

Motorola -format

n

n

Art.-Nr. 22-01-092

n

Содержание LD-G-10

Страница 1: ...comotive Decoder with load control for DC engines Motorola format n Anleitung n Manual Décodeur avec compensation de charge pour locomotive avec moteur continu Format Motorola n Mode d emploi n Handleiding Lastgeregelde Locdecoder voor gelijkstroommotoren Motorola format n n Art Nr 22 01 092 n ...

Страница 2: ... any means electronic or mechanical including photocopying without prior permission in writing from Tams Elektronik GmbH Subject to technical modification 09 2007 Tams Elektronik GmbH Tout droits réservés en particulier les droits de reproduction et de diffusion ainsi que le traduction Toute duplication ou reproduction sous quelque forme que ce soit nécessite l accord écrit de la societé Tams Elek...

Страница 3: ...fe and correct soldering 37 Mounting the locomotive decoder 38 Programming the locomotive decoder 40 Operation 46 FAQ 47 Manufacturer s note 48 Certification 48 Conditional warranty 49 Connections Fig 1 I Circuit Diagram Fig 2 II Pages I to II in the centre of this handbook are removeable The following manufacturers and their products are mentioned in this manual Märklin Cie GmbH Goeppingen German...

Страница 4: ... manual with it Intended use The locomotive decoder is designed for mounting in a model train with DC motor It evaluates the Motorola format data sent by the digital central unit to its address and controls the locomotive s motor and additional functions The module should not be mounted by children under the age of 14 Reading understanding and following the instructions in this manual are mandator...

Страница 5: ...an specified impermissibly high humidity condensation build up can cause serious injury due to electrical shock Take the following precautions to prevent this danger Never perform wiring on a powered module Mounting the module should only be done in closed clean dry rooms Beware of humidity Only use low power for this module as described in this manual and only use certified transformers Connect t...

Страница 6: ...fully when soldering and remove liquid solder with a thick wet rag or wet sponge from the soldering tip Dangerous environments A working area that is too small or cramped is unsuitable and can cause accidents fires and injury Prevent this by working in a clean dry room with enough freedom of movement Other dangers Children can cause any of the accidents mentioned above because they are inattentive...

Страница 7: ...To guarantee the electromagnetic tolerance in operation you must take the following precautions Connect the transformer only to an approved mains socket installed by an authorised electrician Make no changes to the original parts and accurately follow the instructions circuit diagram and PCB layut included with this manual Use only original spare parts if you have to repair the kit or the ready bu...

Страница 8: ... recognizes automatically if it is run in analogue or digital mode and sets the corresponding operation mode The automatic recognition of the analogue mode can be switched off by programming the decoder accordingly The decoder is not suitable for being operated in analogue model railway layouts run with an D C speed control The decoder evaluates the data received in such layouts as braking section...

Страница 9: ...e optimal values of the load control s parameters for the connected DC motor The range of values from which the decoder chooses the optimal value can be altered by programming the decoder accordingly Direction of motion When changing the direction in digital operation the existing direction is saved and so retained even if the central unit does not send absolute driving data e g in Motorola I form...

Страница 10: ...velocity the decoder generates a velocity characteristic corresponding to the opposite figure This characteristic allows a good fine tuning of the speed in the lower speed range Shunting gear The auxiliary function F4 allows you to switch into the shunting gear mode In the shunting gear mode the velocity of all speed levels is reduced to ca 25 compared to the standard velocity Acceleration and bra...

Страница 11: ... some points according to the differences between both formats In particular programming the decoder on a DCC programming track is not possible Online programming Alternatively to the CV programming it is possible to program the address and the driving characteristics online This means Right after starting the programming mode your can enter the new address and directly save it While programming t...

Страница 12: ...ture in storage 10 80 C Comparative humidity allowed max 85 Dimensions approx 12 5 x 9 x 2 3 mm Weight approx 1 1 g Checking the package contents Check the contents of the package for completeness after unpacking one decoder one manual Required tools and consumables Make sure you have the following tools and materials ready for use an electronic soldering iron max 30 Watt with a fine tip a solderi...

Страница 13: ...ring tip to the soldering spot in such a way that the wire and the soldering eye are heated at the same time Simultaneously add solder not too much As soon as the solder becomes liquid take it away Hold the soldering tip at the spot for a few seconds so that the solder flows into the joint then remove the soldering iron The joint should be held still for about 5 seconds after soldering To make a g...

Страница 14: ...rference Solder the red wire to the right rail current collector and the black wire to the left rail current collector in direction of motion Next solder the grey and the orange wires to the motor In case the locomotive s direction of motion does not match the set direction of motion you have to swap the motor connections grey and orange wire Connecting the lighting and other accessories Before co...

Страница 15: ...mitting diodes LEDs you must always operate them via a series resistor LEDs are available in many different models The series resistor limits the current flow of the LED and will need to be calculated for each model Ask for the max current rating when buying your LEDs You can connect several LEDs in parallel to each output In this case every LED must have a series resistor of its own If you connec...

Страница 16: ...decoder via CV programming it is sufficient to put the locomotive on a track section Please note You must connect the track oval or track section to the digital control s track output and not to control unit s output for the DCC programming track Reset the central unit by simultaneously pushing the buttons stop and go for some time or quickly switch the central unit on and off First enter the curr...

Страница 17: ...itch off the track voltage Operate the direction switch and hold it in that position Briefly push the button go As soon as the lighting flashes release the direction switch NO Intellibox Set the current address or address 80 Set all functions to off Start CV programming or one of 4 online programming steps Starting the programming mode Set address back to Motorola II format YES ...

Страница 18: ...t to programm by setting the CV s number as Motorola locomotive address at your central unit 2 Operate the direction switch The locomotive s lighting stops flashing 3 Set the desired value of the CV by setting the CV s value as Motorola locomotive address at your central unit 4 Operate the direction switch again The locomotive s lighting starts flashing again Repeat the steps 1 to 4 for all CVs yo...

Страница 19: ...is CV 9 100 200 150 Analogue voltage needed for change of direction 10 Not used 11 60 120 78 Shut off temperature with overheating The value 78 corresponds to a temperature of 60 C Raising the value leads to a reduction of the sensivity of the overheating protection A too high reduction can cause damage 12 15 Not used 16 43 0 255 Velocity table for velocity characteristic You can assign an individ...

Страница 20: ...ng driving operation setting the starting and the maximum velocity and verifying the settings during driving operation After having entered a new address or performing a decoder reset the decoder automatically returns to standard driving operation After having set and saved the acceleration and braking delay or the starting and the maximum velocity the decoder first remains in the programming mode...

Страница 21: ...e decoder automatically returns to standard driving operation Setting the acceleration and braking delay Start the programming mode see above The locomotive s lighting flashes regularly Switch on function F1 Tip With the online programming it is not possible to set the acceleration and the braking delay individually This can be done with the CV programming only The locomotive s lighting flashes in...

Страница 22: ...ocity Switch on and off function f0 once The settings are saved and the locomotive s lighting flashes intermittently The decoder changes to the setting of the starting velocity the locomotive runs slower Push Stop The programming mode is finished Operation Acceleration and brake delay In Motorola II format the acceleration and brake delay is switched alternately on or off by switching on the funct...

Страница 23: ...nt à Perform a decoder reset and program the decoder anew The locomotive does not run in analogue mode Possible cause The analogue mode is switched off à Alter the value for CV 6 Possible cause The analogue model railway layout is run with a D C speed control the analogue mode however is only possible with A C speed controls In digital mode the locomotive suddenly runs very fast Possible cause Int...

Страница 24: ...y cause a too high current consumption The locomotived does not react to F3 or F4 Possible cause The central unit is set to Motorola I format à Set the central unit to Motorola II format If you cannot find the problem please return the decoder for repair address on the cover page Manufacturer s note The person who brings the circuit into operation is the manufacturer of the product If he sells the...

Страница 25: ...r return the purchase price The following invalidate the warranty using an unsuitable soldering iron solder containing liquid acids or similar if damage is caused by not following the instructions in this manual if the module has been altered and repair attempts have failed if arbitrary changes in the circuit are made if additional components are added which are not described in the manual if the ...

Страница 26: ...otteur Sleper X4 schwarz black noir zwart Gehäuse Housing Masse Huis X5 weiß white blanc wit Beleuchtung vorne Front lighting Feux avant Verlichting voor oder or ou of Beliebiger Verbraucher Optional accessory Consommateur quelconque Gewenste verbruiker X6 gelb yellow jaune geel Beleuchtung hinten Back lighting Feux arrière Verlichting achter oder or ou of Beliebiger Verbraucher Optional accessory...

Страница 27: ...LD G 10 LD G 10 Seite Page Page Pagina II Seite Page Page Pagina II Fig 2 Schaltplan Circuit diagram Schéma de principe Schakelschema ...

Страница 28: ...ls Actuele informatie en tips n http www tams online de n n n n Garantie und Service Warranty and service n Garantie et service Garantie en service n n Tams Elektronik GmbH n Rupsteinstraße 10 D 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail info tams online de n ...