12-9-24
Chapter 12
Inverter Function
Set-up procedures of IVMS start mode
Set the protection for the PM motor.
• Setting the over current detection level [bb160]
• Setting the electronic thermal level [bc110]
Set the PM motor's Plate Data.
• Setting the capacitance [Hd102]
• Setting the number of poles [Hd103]
• Setting the base frequency [Hd104]
• Setting the maximum frequency [Hd105]
• Setting the rated voltage [Hd106]
• Setting the rated current [Hd108]
Set the PM motor constants.
• Setting the motor constant R [Hd110].
• Setting the motor constant Ld [Hd112].
• Setting the motor constant Lq [Hd114].
• Setting the motor constant Ke [Hd116].
• Setting the motor constant J [Hd118].
Conduct the IVMS auto-tuning
• Set the control mode [AA121] at 12 (SM-IVMS).
• Set the auto-tuning selection [HA-01] at 03 (IVMS).
• Input the command for starting the auto-tuning
(operation command).
• The inverter is in an automatic operation.
• Tuning is finished.
• The over-current detection level should be set
appropriately by taking into account the maximum
current (demagnetization level) of the PM motor to
be used. Set the over-current detection level so
that the SM (PMM)'s maximum current
(demagnetization level) is not below 150% of the
over-current detection level.
• See also "12.7.1 Conduct the electronic thermal
protection on motors," and set it appropriately
• See also "12.3.1 Set plate data of motor as
parameters," and set them appropriately.
• See also "12.3.2 Set Motor Constants" and set
them appropriately.
• For the procedures from the auto-tuning start to the
auto-tuning finish, check "12.3.3 Auto-tune
motor," and follow the procedures.
• In the IVMS auto-tuning, the tuning should be done
as the motor shaft is being rotated little by little.
When the motor shaft is locked, or when the load is
heavy, even a normal finish of the auto-tuning may
result in a adjustment failure. Conduct the IVMS
auto-tuning with nothing attached to the motor
shaft.
• When an over current occurs during the automatic
operation of the IVMS auto-tuning, check the
following items.
(1) Motor lock caused by braking and/or foreign
objects.
(2) Setting over-current detection level [bb160]
Check these items, and when there is no problem,
conduct the IVMS auto-tuning by incrementing the
minimum pulse width adjustment [Hd-50] by 10
each time.
• It may take approximately 5 minute to conduct the
IVMS auto-tuning.
▼
1
2
3
4
!
Содержание SJ Series
Страница 39: ...5 4 Chapter 5 Included Items Memo ...
Страница 52: ...6 13 Chapter 6 Installation Model P1 P1 200V class P1 02950 L P1 550L Dimension W mm H mm D mm 480 700 250 ...
Страница 55: ...6 16 Chapter 6 Installation Memo ...
Страница 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Страница 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Страница 145: ...10 10 Chapter 10 Test Run Memo ...
Страница 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Страница 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Страница 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Страница 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Страница 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Страница 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Страница 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Страница 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Страница 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Страница 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Страница 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Страница 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Страница 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Страница 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Страница 661: ...20 11 Chapter 20 Specifications Model P1 P1 200V class 02950 L 550L Dimension W mm H mm D mm 700 480 250 ...
Страница 662: ...20 12 Chapter 20 Specifications Model P1 P1 400V class 01760 H 750H 02130 H 900H Dimension W mm H mm D mm 390 700 270 ...
Страница 663: ...20 13 Chapter 20 Specifications Model P1 P1 400V class 02520 H 1100H 03160 H 1320H Dimension W mm H mm D mm 480 740 270 ...
Страница 678: ...21 7 Chapter 21 Technical Notes SJ700D SJ P1 ND normal duty SJ700D 550LFF3 P1 02950 LFEF P1 550LFF ...
Страница 686: ...21 15 Chapter 21 Technical Notes SJ700B SJ P1 LD low duty VLD very low duty SJ700B 750LFF P1 02950 LFEF P1 550LFF ...
Страница 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...