20-3
Chapter 20
Specifications
20.2.2
400V Class Specifications
*1)
The values shown are ratings when carrier frequency is at 2kHz.
Please
use the inverter in accordance with "20.4 Current Derating Table".
*2)
The rated input currents shown in the table are the values when the rated
current is output.
The values vary depending on impedance on the
power supply (wiring, breaker, input reactor option, etc.)
*3)
The following shows response to the Low Voltage Directive.
- Pollution degree 2
- Overvoltage category 3 (when input voltage is between 380 and 460
VAC)
- Overvoltage category 2 (when input voltage is higher than 460 VAC)
*4)
The power supply equipment capacities shown in the table are the
values when 440V rated current is output.
The values vary depending on
impedance on the power supply (wiring, breaker, input reactor option,
etc.)
*5)
The setting of rated values for carrier frequencies [bb101]/[bb201] are
internally limited in accordance with the description.
Also, it is
recommended to set values equivalent to or above (maximum output
frequency for driving ×10) Hz for the setting of carrier frequencies
[bb101]/[bb201]. Also, in the case of induction motor (IM) control, for
items other than those subject to V/f control, it is recommended to set
carrier frequency at 2kHz or more. In the case of synchronous motor
(SM)/permanent magnet motor (PMM) control, it is recommended to set
carrier frequency at 8kHz or more.
* The models in 400V class are shown as P1-*****-HFF or
P1-*****-HFEF, P1-*****-HFUF, or P1-*****-HFCF.***** filled with
numbers described in "Model symbol".
*6)
Values when sensorless vector control is applied at ND rating on a
Hitachi's standard motor.
Torque characteristics may be different
depending on the control method or motor for use.
*7)
The dimensions do not include buttons on the operator keypad.
When optional items are connected, the required dimensions will
increase. Check the instruction manuals of each optional item for details.
*8)
Usually a regenerative braking unit needs to e separately installed,
however, in response to your order, we can install the braking circuit
internally and attach a discharging resistor, thereby eliminating the need
for the regenerative braking unit.
Please contact the sales officer of our
company shown in the back cover.
Model symbol
P1-*****-H
00041 00054 00083 00126 00175 00250 00310 00400 00470 00620 00770 00930 01160 01470 01760 02130 02520 03160
ND capacity standard notation
P1-***H
007
015
022
037
055
075
110
150
185
220 300
370
450
550
750
900 1100 1320
Applicable motor (4-pole)
capacity (kW)
VLD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132 160
LD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132 160
ND
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Output
Rated output
current (A)
VLD
4.1
5.4
8.3
12.6 17.5 25.0 31.0 40.0 47.0 62.0 77.0 93.0 116
147
176
213
252 316
LD
3.1
4.8
6.7
11.1 16.0 22.0 29.0 37.0 43.0 57.0 70.0 85.0 105
135
160
195
230 290
ND
2.5
4.0
5.5
9.2
14.8 19.0 25.0 32.0 39.0 48.0 61.0 75.0 91.0 112
150
180
217 260
Overload current
rating
VLD
110% 60sec / 120% 3sec
LD
120% 60sec / 150% 3sec
ND
150% 60sec / 200% 3sec
Rated output voltage
3-phase (3-wire) 380-500V (depending on receiving voltage)
Rated
capacity
(kVA)
400V
VLD
2.8
3.7
5.8
8.7
12.1 17.3 21.5 27.7 32.6 43.0 53.3 64.4 80.4 101.8 121.9 147.6 174.6 218.9
LD
2.1
3.3
4.6
7.7
11.1 15.2 20.1 25.6 29.8 39.5 48.5 58.9 72.7 93.5 110.9 135.1 159.3 200.9
ND
1.7
2.8
3.8
6.4
10.3 13.2 17.3 22.2 27.0 33.3 42.3 52.0 63.0 77.6 103.9 124.7 150.3 180.1
500V
VLD
3.6
4.7
7.2
10.9 15.2 21.7 26.8 34.6 40.7 53.7 66.7 80.5 100.5 127.3 152.4 184.5 218.2 273.7
LD
2.7
4.2
5.8
9.6
13.9 19.1 25.1 32.0 37.2 49.4 60.6 73.6 90.9 116.9 138.6 168.9 199.2 251.1
ND
2.2
3.5
4.8
8.0
12.8 16.5 21.7 27.7 33.8 41.6 52.8 65.0 78.8 97.0 129.9 155.9 187.9 225.2
Input
Rated input current
(A) *1)
VLD
4.9
6.4
9.9
15.0 20.8 29.8 36.9 47.6 56.0 73.8 91.7 110.7 138.1 175.0 209.5 253.6 300.0 376.2
LD
3.7
5.7
8.0
13.2 19.0 26.2 34.5 44.0 51.2 67.9 83.3 101.2 125.0 160.7 190.5 232.1 273.8 345.2
ND
3.0
4.8
6.5
11.0 17.6 22.6 29.8 38.1 46.4 57.1 72.6 89.3 108.3 133.3 178.6 214.3 258.3 309.5
Rated input AC voltage *2)
Control power supply: Power supply single phase 380-500V (allowable variation range 323-550V),
50Hz (allowable variation range: 47.5-52.5Hz)/60Hz (allowable variation range: 57-63Hz)
Main circuit power supply: 3-phase (3-wire) 380-500V (allowable variation range) 323-550V,
50Hz (allowable variation range: 47.5-52.5Hz)/60Hz (allowable variation range: 57-63Hz)
Power supply
equipment capacity
(kVA) *3)
VLD
3.7
4.9
7.5
11.4 15.9 22.7 28.1 36.3 42.6 56.3 69.9 84.4 105.2 133.4 159.7 193.2 228.6 286.7
LD
2.8
4.4
6.1
10.1 14.5 20.0 26.3 33.6 39.0 51.7 63.5 77.1 95.3 122.5 145.2 176.9 208.7 263.1
ND
2.3
3.6
5.0
8.3
13.4 17.2 22.7 29.0 35.4 43.5 55.3 68.0 82.6 101.6 136.1 163.3 196.9 235.9
Carrier frequency range *4)
VLD
0.5~10.0kHz
0.5~8.0kHz
LD
0.5~12.0kHz
0.5~8.0kHz
ND
0.5~16.0kHz
0.5~10.0kHz
Motor start torque*5)
200%/0.3Hz
180%/0.3Hz
Braking
Regenerative braking
Equipped with braking resistance circuit
(with a discharging resistor separately installed)
*6)
Regenerative braking unit
separately installed
Minimum resistance that
can be connected (Ω)
100
100
100
70
70
35
35
24
24
20
15
15
10
10
-
-
-
-
Dimension
*7)
H (height) (mm)
255
255
255
255
260
260
260
390
390
390 540
550
550
550
700
700
740 740
W (width) (mm)
150
150
150
150
210
210
210
245
245
245 300
390
390
390
390
390
480 480
D (depth) (mm)
140
140
140
140
170
170
170
190
190
190 195
250
250
250
270
270
270 270
Protective construction
IP20 / UL open type
Approximate mass (kg)
3
3
3
3
7
7
7
16
16
16
22
30
30
30
55
55
70
70
Содержание SJ Series
Страница 39: ...5 4 Chapter 5 Included Items Memo ...
Страница 52: ...6 13 Chapter 6 Installation Model P1 P1 200V class P1 02950 L P1 550L Dimension W mm H mm D mm 480 700 250 ...
Страница 55: ...6 16 Chapter 6 Installation Memo ...
Страница 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Страница 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Страница 145: ...10 10 Chapter 10 Test Run Memo ...
Страница 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Страница 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Страница 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Страница 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Страница 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Страница 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Страница 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Страница 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Страница 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Страница 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Страница 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Страница 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Страница 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Страница 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Страница 661: ...20 11 Chapter 20 Specifications Model P1 P1 200V class 02950 L 550L Dimension W mm H mm D mm 700 480 250 ...
Страница 662: ...20 12 Chapter 20 Specifications Model P1 P1 400V class 01760 H 750H 02130 H 900H Dimension W mm H mm D mm 390 700 270 ...
Страница 663: ...20 13 Chapter 20 Specifications Model P1 P1 400V class 02520 H 1100H 03160 H 1320H Dimension W mm H mm D mm 480 740 270 ...
Страница 678: ...21 7 Chapter 21 Technical Notes SJ700D SJ P1 ND normal duty SJ700D 550LFF3 P1 02950 LFEF P1 550LFF ...
Страница 686: ...21 15 Chapter 21 Technical Notes SJ700B SJ P1 LD low duty VLD very low duty SJ700B 750LFF P1 02950 LFEF P1 550LFF ...
Страница 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...