12-13-3
Chapter 12
Inverter Function
12.13.2
Restraining to avoid overcurrent
• Impact load can cause overcurrent tripping.
• I would like to avoid tripping against momentary
current increase.
• I want to accelerate while suppressing the motor
current.
• I want to prevent tripping caused by sudden
fluctuation of load.
• Setting [bA120] overcurrent suppression selection
to 01 enables the overcurrent suppression function.
• This function suppresses the overcurrent caused
by steep current
increase due to sudden acceleration, etc.
Parameters
• Disable this function when using for elevators, etc.
Suppressing the current causes insufficient torque,
which may result in sliding down of the panier or
anything hanging.
• The overcurrent tripping may take place even if this
function is enabled if the current increases sharply
due to shock load, etc.
• This function will be automatically enabled during
DC braking.
• If the overcurrent suppression function is enabled,
the overcurrent suppression function will be
activated when the motor current exceeds the set
value for [bA121] with momentary current increase.
*1) See "12.14.4 Starting with frequency pull-in" for
details.
Item
Parameter
Data
Description
Overcurrent suppression
selection
[bA120]
00
Disabled
01
Enabled (Overcurrent suppression is
activated.)
Overcurrent suppression
level
[bA121]
Inverter
rated current
×
(0.00~2.00)
Sets the operation level of the
overcurrent suppression function.
Overcurrent suppression
level
when resuming with
frequency pull-in
[bb-46]
Inverter
rated current
×
(0.00~2.00)
Sets the operation level of the
overcurrent suppression function
when activated with frequency
pull-in.*
1)
Q
A
!
Содержание SJ Series
Страница 39: ...5 4 Chapter 5 Included Items Memo ...
Страница 52: ...6 13 Chapter 6 Installation Model P1 P1 200V class P1 02950 L P1 550L Dimension W mm H mm D mm 480 700 250 ...
Страница 55: ...6 16 Chapter 6 Installation Memo ...
Страница 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Страница 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Страница 145: ...10 10 Chapter 10 Test Run Memo ...
Страница 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Страница 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Страница 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Страница 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Страница 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Страница 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Страница 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Страница 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Страница 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Страница 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Страница 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Страница 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Страница 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Страница 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Страница 661: ...20 11 Chapter 20 Specifications Model P1 P1 200V class 02950 L 550L Dimension W mm H mm D mm 700 480 250 ...
Страница 662: ...20 12 Chapter 20 Specifications Model P1 P1 400V class 01760 H 750H 02130 H 900H Dimension W mm H mm D mm 390 700 270 ...
Страница 663: ...20 13 Chapter 20 Specifications Model P1 P1 400V class 02520 H 1100H 03160 H 1320H Dimension W mm H mm D mm 480 740 270 ...
Страница 678: ...21 7 Chapter 21 Technical Notes SJ700D SJ P1 ND normal duty SJ700D 550LFF3 P1 02950 LFEF P1 550LFF ...
Страница 686: ...21 15 Chapter 21 Technical Notes SJ700B SJ P1 LD low duty VLD very low duty SJ700B 750LFF P1 02950 LFEF P1 550LFF ...
Страница 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...