345
10.3.5
TPC Output Triggering by Input Capture
TPC output can be triggered by 16-bit timer input capture as well as by compare match. If GRA
functions as an input capture register in the 16-bit timer channel selected in TPCR, TPC output
will be triggered by the input capture signal. Figure 10.8 shows the timing.
φ
TIOC pin
Input capture
signal
NDR
DR
N
N
M
Figure 10.8 TPC Output Triggering by Input Capture (Example)