171
Timing Charts
IR test (fail judgment): With delay time setting (delay time > rinse time) and contact check (contact
error)
U_FAIL
or
L_FAIL
HV_ON
START
READY
W-FAIL
(TEST)
(PROBE)
(RISE)
(MEAS)
W-MODE
(TEST_END)
(MEAS_END)
HV_ON
START
(TEST)
READY
(PROBE)
(RISE)
(MEAS)
W-MODE
TEST
U_FAIL
(MEAS_END)
CONT_ERR
L_FAIL
(MEAS_END)
W-FAIL
HV_ON
START
(TEST)
(PROBE)
(MEAS)
TEST
READY
IR-FAIL
(TEST_END)
(MEAS_END)
IR-MODE
HV_ON
START
(TEST)
(PROBE)
(RISE)
(RISE)
(MEAS)
TEST
IR-MODE
READY
U_FAIL
(MEAS_END)
CONT_ERR
L_FAIL
(MEAS_END)
IR-FAIL
U_FAIL
or
L_FAIL
TEST
DANGER lamp lit
Rise time
Output voltage
5 ms max.
15 ms typ.
5 ms min.
Test time
Discharge
time
Contact check period
Upper judgment start Lower judgment start
Delay time
3 ms typ.
5 ms max.
5 ms max.
3 ms typ.
External Control (EXT
. I/O)
HIOKI ST5680A961-00