Basic information | Control model, software and features
1
The parameters
Q429
COOLANT ON
and
Q430
COOLANT OFF
in Cycle
241
SINGLE-LIP D.H.DRLNG
(ISO:
G241
, option 19) have
been enhanced. You can define a path for a user macro.
An input value of 2 has been added to parameter
Q575
INFEED
STRATEGY
in Cycle
272
OCM ROUGHING
(ISO:
G272
, option 167).
With this input option, the control calculates the machining
sequence so that the tooth length of the tool is used to its full
extent.
Certain cycles permit you to enter tolerances. In the following
cycles, you can define dimensions, tolerances according to DIN
EN ISO 286-2 or general tolerances according to DIN ISO 2768-1:
Cycle
208
BORE MILLING
(ISO: G208, option 19)
Cycle
1271
OCM RECTANGLE
(ISO: G1271, option 167)
Cycle
1272
OCM CIRCLE
(ISO: G1272, option 167)
Cycle
1273
OCM SLOT / RIDGE
(ISO: G1273, option 167)
Cycle
1278
OCM POLYGON
(ISO: G1278, option 167)
Further information:
User's Manual for
Programming of Measuring
Cycles for Workpieces and Tools
The unit of measurement of the main program can be seen in the
header of the log file of the Probing Cycles
14xx
and
42x
If a basic rotation is active in the workpiece preset, the control
shows an error message during execution of the Cycles
451
MEASURE KINEMATICS
(ISO:
G451
, option 48),
452
,
PRESET
COMPENSATION
(ISO:
G452
, option 48). The control resets the
basic rotation to 0 during continuation of the program.
The parameter
Q523
TT-POSITION
has been added to Cycle
484
CALIBRATE IR TT
(ISO:
G484
). This parameter allows you
to define the position of the tool touch probe and, if desired, to
transfer the position to the machine parameter
centerPos
after
calibration.
The Cycles
1420
PROBING IN PLANE
(ISO:
G1420
),
1410
PROBING ON EDGE
(ISO:
G1410
),
1411
PROBING TWO CIRCLES
(ISO:
G1411
) have been enhanced:
In these cycles, you can define tolerances according to DIN
EN ISO 286-2 or general tolerances according to DIN ISO
2768-1.
If you defined the value 2 in parameter
Q1125
CLEAR.
HEIGHT MODE
, the control positions the touch probe at
rapid traverse
FMAX
from the touch probe table to the set-up
clearance.
42
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 01/2022
Содержание TNC 620
Страница 4: ...Contents 4 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 6: ...Contents 6 HEIDENHAIN TNC 620 User s Manual for Setup Testing and Running NC Programs 01 2022...
Страница 24: ......
Страница 25: ...1 Basic information...
Страница 43: ...2 First steps...
Страница 55: ...3 Fundamentals...
Страница 126: ......
Страница 127: ...4 Tools...
Страница 165: ...5 Setup...
Страница 245: ...6 Testing and running...
Страница 311: ...7 Special functions...
Страница 316: ......
Страница 317: ...8 Pallets...
Страница 339: ...9 MOD functions...
Страница 368: ......
Страница 369: ...10 HEROS functions...
Страница 470: ......
Страница 471: ...11 Operating the touchscreen...
Страница 488: ......
Страница 489: ...12 Tables and overviews...