8 Troubleshooting – Possible faults
164
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
WA210
Lambda sensor
Heating faulty
•
Heating element of lambda
sensor faulty
•
Lambda sensor faulty
•
Relay in control cabinet
faulty
•
Fuse F12 blown
•
Check the electrical
connection
•
Replace lambda sensor
•
Replace relay
•
Unlock automatic circuit
breaker F12
WA211
Lambda sensor
sensor
•
Heating element of lambda
sensor faulty
•
Lambda sensor faulty
•
Analogue module faulty
•
Check the electrical
connection
•
Replace lambda sensor
•
Check analogue module
WA212
Lambda sensor
faulty
•
Heating element of lambda
sensor faulty
•
Lambda sensor faulty
•
Analogue module faulty
•
Check the electrical
connection
•
Replace lambda sensor
•
Check analogue module
WA213
Check pellet
container
filling level
•
Pellet storage space empty
•
Check pellet storage space
and fill if necessary
WA215
Runtime vacuum
junction,
anticlockwise
•
Tube converter blocked
•
Faulty reference limit switch
•
Fuse triggered
•
Motor incorrectly connected
•
Motor overload
•
Motor is faulty
•
Motor cable faulty
•
Check tube converter
•
Check reference limit switch
•
Check fuse
•
Check the motor connection
•
Check the drive
•
Check the motor
•
Check the motor cable
WA216
Runtime vacuum
junction,
clockwise
•
Tube converter blocked
•
Faulty reference limit switch
•
Fuse triggered
•
Motor incorrectly connected
•
Motor overload
•
Motor is faulty
•
Motor cable faulty
•
Check tube converter
•
Check position limit switch
•
Check fuse
•
Check the motor connection
•
Check the drive
•
Check the motor
•
Check the motor cable
WA217
Walking floor
not enabled
•
Switch in control cabinet not
switched on
•
Fault not acknowledged
•
Switch on the switch in the
control cabinet
•
Acknowledge fault
WA218
Walking floor is
switched off
•
Information on walking floor
activity
WA224
Boiler-2 faulty
•
Fault with boiler 2
•
Remove fault
WA225
Please empty ash
box!
•
Set monitoring time for ash
removal augers exceeded
•
Empty ash box
•
Reset time in the parameter
11-04
with
RESET
No.
Fault
Cause
Remedy
Table 8/1 - Faults (continuation)
Содержание M299
Страница 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Страница 2: ......
Страница 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 173: ...173 NOTICE ...
Страница 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 175: ......