HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – °C/QUANTITY menu
91
M
ODIFYING
THE
WALKING
FLOOR
SETTING
A walking floor delivery system can be an optional component of a
heating system. The individual scraper blades of the walking floor
can be separately controlled.
•
Off
In this version, all scraper blades are switched off.
•
Auto scraper 1
In this version, only scraper 1 of the walking floor is controlled.
•
Auto scraper 2
In this version, only scraper 2 of the walking floor is controlled.
•
Auto scraper 1 + 2
In this version, both scraper blades of the walking floor are
alternately controlled.
•
MANUAL
In this version, the walking floor scrapers can be controlled by hand.
The manual control function in the
Manual
menu is enabled.
✎
See “Procedure” in this section.
6.7 °C/QUANTITY menu
In this menu, you can view and set temperatures, combustion air
quantity, fuel type/quantity and control parameters. All target values
can be modified. The actual values displayed indicate the current
status.
P
ROCEDURE
1.
Press the
F2
key under the standard display screen.
✓
You are in the
°C/Quantity
menu.
2.
Scroll with the
F1
or
F2
key to the previous or next submenu.
✓
The first resettable parameter is shown in black.
3.
Enter the desired value using the numerical keypad.
Setting
1-07
Walking floor
: MANUAL
FIELD
END
Содержание M299
Страница 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Страница 2: ......
Страница 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 173: ...173 NOTICE ...
Страница 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 175: ......