6 Using the heating system – °C/QUANTITY menu
92
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
4.
Confirm each change with the
Enter
key.
✓
The desired parameter is set.
5.
Scroll with the
Up
or
Down
key to the next parameter.
✓
The next resettable parameter is shown in black.
6.
Repeat steps 3 to 5 for additional parameters.
7.
Press the
F6
key under the
END
command to exit the submenu.
✓
The standard display is restored.
D
EFINING
THE
SWITCH
ON
/
OFF
TIMES
FOR
THE
BOILER
This submenu is used to define the switch on/off times of the boiler
based on the temperature sensor of the accumulator. The switching
on and off of the boiler can be changed by adapting the
temperature.
•
Temp. acc. top below
If this temperature set for the top accumulator sensor is not met, the
boiler switches back on.
•
Temp. acc. bottom above
If the temperature set for the bottom accumulator sensor is
exceeded, the boiler switches off.
✎
See “Procedure” in this section.
Temperature adjustment using the accumulator sensors is only
available if the boiler activation is set to “Accumulator temperature
sensor”.
✎
See section “6.6 ON/OFF menu”, under “Selecting and setting
boiler activation”.
Boiler on/off
2-11
On: acc. top below
:
70 / 70°C
acc. temp. middle
:
60°C
Off: acc. bottom above
:
70 / 57°C
END
The standard setting for the boiler switch-on temperature for
acc.
top below
is 70 °C.
The standard setting for the boiler switch-off temperature for
acc.
bottom above
is 70 °C.
Содержание M299
Страница 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Страница 2: ......
Страница 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 173: ...173 NOTICE ...
Страница 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 175: ......