HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – ON/OFF menu
89
✎
For the setting of the minimum lambda value, see section “6.7 °C/
QUANTITY menu”, paragraph “Entering the residual oxygen
setting”.
M
ODIFYING
FAN
SETTINGS
This submenu is used to change the settings for the flue gas fan or
the primary and secondary air fans. Setting options:
•
Controlled
On this setting the flue gas fan works at a set speed according to the
existing vacuum pressure conditions.
•
Not controlled
On this setting the flue gas fan works at a constant preset value.
✎
See “Procedure” in this section.
A
DJUSTING
THE
ASH
REMOVAL
SETTING
The movement of the stepped grate and the ash removal system can
be switched off.
✎
See “Procedure” in this section.
Setting 1-03
Flue gas fan
: controlled
Primary air fan
: controlled
Secondary air fan
: controlled
FIELD
END
The standard setting is
controlled
.
Setting
1-04
De-ashing
: Automatic
CHOOSE
END
The standard setting is
Automatic
.