6 Using the heating system – SERVICE menu
117
When this set temperature is exceeded, the fault message “Flue gas
temperature too high” appears and the boiler switches off.
•
Delay error
The fault message “Flue gas temperature too high” appears after this
set delay time has elapsed.
•
Increase
System-specific parameter, can only be set and modified by
authorised HDG technicians.
✎
See “Procedure” in this section.
S
ETTING
INTERFACE
RS485
•
Interface RS485
Setting options:
– without interface
– Modbus RTU web server
– Modbus RTU DDC
– Profibus DP DDC
✎
See “Procedure” in this section.
S
ETTING
M
ODBUS
RTU - W
EB
SERVER
The address of the controller can be set here (especially with multiple
systems).
Flue gas temperature
5-14
Cleaning system start
:
220 / 50 °C
Maximum flue gas temp. :
250 / 50 °C
Delay error :
1.0 m
Increase
2
END
Interface parameters
5-17
Function RS485-1
:without interface
EDIT
END