HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – TIME menu
97
✓
The first resettable parameter is shown in black.
3.
Enter the desired value using the numerical keypad.
4.
Confirm each change with the
Enter
key.
✓
The desired parameter is set.
5.
Scroll with the
Up
or
Down
key to the next parameter.
✓
The next resettable parameter is shown in black.
6.
Repeat steps 3 to 5 for additional parameters.
7.
Press the
F6
key under the
END
command to exit the submenu.
✓
The standard display is restored.
S
ETTING
THE
FILLING
,
IGNITION
AND
FAN
ACTIVATION
This submenu is used to set the time for the initial filling with fuel and
the running time of the ignition fan. You can also set the time after
which the combustion fan is added during the igniting phase.
✎
See “Procedure” in this section.
S
ETTING
PRE
-
AIR
,
HEATING
UP
AND
BURNING
OUT
This submenu enables you to set the pre-ventilation time for fanning
the fuel without material feeding, the heating up time during which
the fuel quantity is heated to the target value, and the burn-out time
during which material feeding is stopped and the combustion fan
switches off after a specified time.
✎
See “Procedure” in this section.
Time
3-01
1st filling
:
10.0 / 0.0 m
Ignition
:
7.0 / 0.0 m
Start combustion air fan
:
1.0 / 0.0 m
END
When changing the fuel, the parameters
1st filling
and
Ignition
must be regulated to avoid malfunctions during
ignition.
Time
3-02
Содержание M299
Страница 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Страница 2: ......
Страница 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 173: ...173 NOTICE ...
Страница 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 175: ......