6 Using the heating system – Performing the chimney sweep test
130
HDG M299/300/350/400 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
2.
Press the
F4
key under the “
Chimney sweep test
” symbol.
✓
You are now in the
Chimney sweep test 5-02
submenu.
3.
Press the
F3
key under the
30%
command to start the chimney
sweep test in partial load operation.
4.
Press the
F4
key under the
100%
command to start the chimney
sweep test in nominal load operation.
✓
The
Heating up
message appears in the display.
✓
Once the specified temperatures have been reached, the display
shows the
Measurement enabled
message.
✓
The measurement is carried out.
Chimney sweep mode
5-11
Heating OFF
Enable boiler temperature :
75 / 0 °C
Enable comb. chamb. temp. :
450 / 0 °C
Measurement duration :
75 / 0 m
30%
100%
END
When operating the heating system without an accumulator, the
chimney sweep test can also be carried out in partial load operation
with 30% of the nominal thermal power.
Press the
F6
key under the
End
command to cancel the chimney
sweep test.
The chimney sweep test is also cancelled if the specified
measurement duration is exceeded.