HDG Bavaria GmbH 07/2008
HDG M299/300/350/400 - Version 1 - en
6 Using the heating system – Switching off the heating system
81
P
ROCEDURE
1.
Turn the heating system main switch on.
✓
The control is activated.
✓
After a start-up phase, the display will first of all show a switch-on
message and then the standard display.
2.
Set the engage switch to “1”.
✓
The display switches to
Heating ON
.
✓
The heating system is now switched on.
6.3 Switching off the heating system
The heating system can be switched off from any operating mode.
1.
Set the engage switch to “0”.
✓
The heating system is switched off; the supplying of fuel is
stopped; the combustion air fan continues running for a preset
burn-out time.
2.
Allow the heating system to burn out until the combustion air fan
switches off.
3.
Turn the heating system main switch off.
✓
No operating mode is displayed on the control unit of the HDG
Control.
✓
The heating system has been de-energised.
6.4 Operating statuses
The heating system goes through the following states during
operation:
Warning!
Frost danger!
Only switch off the heating system completely if you are certain
there is no danger of frost.
Operating status
Description
Heating OFF
•
The main switch is turned on.
•
The engage switch is at “0”.
1st filling
combustion chamber
•
The current combustion chamber temperature is lower than the
preset ignition temperature.
•
This operating status is maintained until the preset time for filling
the combustion chamber has been reached, the fill level indicator
signals or the combustion chamber temperature exceeds the
ignition temperature.
Table 6/1 - Operating statuses
Содержание M299
Страница 1: ...hdg bavaria com HDG M299 300 350 400 Operation Manual ...
Страница 2: ......
Страница 172: ...172 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 173: ...173 NOTICE ...
Страница 174: ...174 HDG M299 300 350 400 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 175: ......