TELEDYNE DETCON MODEL SW-A2V2-DV2 

Hazardous Duty Class 1 Division 2 Multi-tone Alarm Station 

 

 

 

Operator’s Installation and Instruction Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 Teledyne Detcon, Inc. 

4055 Technology Forest Blvd. Suite 100 

The Woodlands, Texas 77381 

Ph.713.559.9200 / Fax 713.893.6729 

www.teledynegasandflamedetection.com

   

 

December 3, 2019 • Document # 4572 • Revision 0.3 

Содержание SW-A2V2-DV2

Страница 1: ...Multi tone Alarm Station Operator s Installation and Instruction Manual Teledyne Detcon Inc 4055 Technology Forest Blvd Suite 100 The Woodlands Texas 77381 Ph 713 559 9200 Fax 713 893 6729 www teledyn...

Страница 2: ...SW A2V2 DV2 SW A2V2 DV2 Instruction Manual ii This page left intentionally blank...

Страница 3: ...ervice and Maintenance 9 4 1 Replacement of the battery pack 9 5 0 Parts List 10 6 0 Specifications 10 7 0 Warranty 11 8 0 Revision Log 11 Table of Figures Figure 1 Basic Wireless Alarm Stations 1 Fig...

Страница 4: ...hipping Address 4055 Technology Forest Blvd Suite 100 The Woodlands Texas 77381 Mailing Address P O Box 8067 The Woodlands Texas 77387 8067 Phone 713 559 9200 Fax 713 893 6729 www teledynegasandflamed...

Страница 5: ...ections The alarm station is powered by two internal battery packs Communication is performed via Detcon RXT 320 transceivers Access to the unit is only necessary for general maintenance and battery e...

Страница 6: ...utilized for monitoring the Battery 1 1 Strobe The alarm station warning light is configured with choice of dome colors such as amber blue clear green magenta or red Dome guard is included The rugged...

Страница 7: ...outside elements Operating periods before recharge will vary based on alarm usage but can be as long as 5 months for the 12V 2900mAh battery pack Improper use of the battery pack may be hazardous to...

Страница 8: ...ction circuitry of the batter pack which prevents any overcharging issues 1 5 RXT Wireless Transceiver The wireless function of the alarm station is made possible by Teledyne Detcon s RXT series wirel...

Страница 9: ...switch is normally set at the factory Each Wireless Alarm Interconnect PCA must have a unique Modbus address to be recognized on the network The alarm station address must be in the range of 0x80 0x8...

Страница 10: ...emove or replace lamps or plug in modules unless power has been disconnected or the area is free of ignitable concentrations CAUTION Explosion Hazard DO NOT disconnect while the circuit is live or unl...

Страница 11: ...ree spaced reliefs are provided for a 3 8 spanner wrench if needed If the cover will not unscrew back out the set screw a few additional turns 3 Loosen the captive Philips screw retaining the printed...

Страница 12: ...low Whoop 11001 Slow Whoop 8 Sweep 1200 500 Hz at 1 Hz 11000 Din Tone 9 Alt Tones 2400 2850 Hz at 2 Hz 10111 10 Int Tone of 970 Hz at 1 Hz 10110 Back Up Alarm LF 11 Alt Tones 800 970 Hz at 7 8 Hz 1010...

Страница 13: ...losion Hazard DO NOT disconnect while the circuit is live or unless the area is free of ignitable concentrations CAUTION Explosion Hazard DO NOT connect or disconnect when energized 4 1 Replacement of...

Страница 14: ...h the same type 6 0 Specifications Input Voltage Battery Current N A Mount Wall Mount or 2 3 Pipe Mount Environment Rating Designed to meet NEMA 4 specifications Area Classification Designed for use i...

Страница 15: ...service policies are FOB the Detcon Inc facility located in The Woodlands Texas 8 0 Revision Log Revision Date Changes made Approval 0 0 03 27 15 Initial Release LU 0 1 05 14 15 Correct manual docume...