7/08/03
888-2463-001
7-33
WARNING: Disconnect primary power prior to servicing.
Section 7 Parts List
Diamond Series™
INDICATES CHANNEL, XX = US
CHANNELS 14-69
484 0530 000 FILTER, UHF DTV, (REFLECTIVE)
0.0 EA (1 REQ’D) (USED WHEN STF
"COOL FUEL" AND VENDOR
ANDREW PPP IS SPECIFIED) LAST
TWO DIGITS OF PART NUMBER
INDICATES CHANNEL, XX = US
CHANNELS 14-69
484 0533 000 FILTER, UHF DTV; (REFLECTIVE)
0.0 EA (1 REQ’D) (USED WHEN STF
"COOL FUEL" AND VENDOR
DIELECTRIC IS SPECIFIED) LAST
TWO DIGITS OF PART NUMBER
INDICATES CHANNEL, XX = US
CHANNELS 14-69
556 0058 000 ATTEN, COAX, N, 3DB, 2 WATT
2.0 EA 1AT4, 1AT5, (#1A10)
556 0134 000 ATTEN, FIXED, 12DB 1/2W SMA
2.0 EA # CONTROL CABINET: RTAC
SAMPLE AT6 AT7
556 0138 000 ATTENUATOR FIXED SMA 10DB
1.0 EA # CONTROL CABINET: RTAC
SAMPLE AT8
620 0639 000 HYBRID 3DB, CA-25N
1.0 EA 1A10
620 2957 004 CIRCULATOR, UHF 1000W
0.0 EA (32 REQ’D FOR 470-518 MHZ)
2CIR1 - 2CIR16, 3CIR1-3CIR16
620 2957 005 CIRCULATOR, UHF 1000W
0.0 EA (32 REQ’D FOR 518-598 MHZ)
2CIR1 -2 CIR16, 3CIR1-3CIR16
620 2957 006 CIRCULATOR, UHF 1000W
0.0 EA (32 REQ’D FOR 596-704 MHZ) CIR1
- CIR16, 3CIR1-3CIR16
620 2957 007 CIRCULATOR, UHF 1000W
0.0 EA (32 REQ’D FOR 701-860 MHZ) CIR1
- CIR16, 3CIR1-3CIR16
620 3034 000 COMBINER, 3DB HYB 470-638MHZ
0.0 EA (1 REQ’D FOR 470-638MHZ,
COMBINES 2 PA CABINETS RF
OUTPUT PORTS)
620 3035 000 COMBINER, 3DB HYB 636-860MHZ
0.0 EA (1 REQ’D FOR 636-860MHZ,
COMBINES 2 PA CABINETS RF
OUTPUT PORTS)
620 3065 001 SPLITTER, POWER 16-WAY
0.0 EA (2 REQ’D FOR 470-638MHZ) 2A31,
3A31
620 3065 002 SPLITTER, POWER 16-WAY
0.0 EA (2 REQ’D FOR 636-860MHZ) 2A31,
3A31
700 0116 000 RES, LOAD 50 OHM 2W
1.0 EA #1A10
700 0628 000 RES, LOAD 5KW 50 OHM
1.0 EA (1 REQ’D, COMBINER REJECT
LOAD)
740 1059 000 MON, PH 430-480V 3PH
0.0 EA (2 REQ’D THIS VOLTAGE)
2A17K2, 3A17K2
740 1139 000 PHASE MONITOR 208V-240V
0.0 EA (2 REQ’D THIS VOLTAGE)
2A17K2, 3A17K2
917 2515 326 PLATE, CABINET SPLITTER
1.0 EA #1A10
917 2515 349 CABLE PACKAGE, HELIAX 2PA
1.0 EA
939 8210 092 SCH LIST, BASIC DIAMOND HP
0.0 EA (COMMON DOCUMENTATION
FOR ALL XMTR POWER LEVELS)
939 8210 126 SCHEMATIC LIST, DHD60P2
0.0 EA (XMTR POWER LEVEL
DEPENDENT DOCUMENTATION)
943 5510 102 3-1/8 TEST LOAD LINE KIT-MYAT
0.0 EA (OPTION, 1 REQ’D IF MYAT RF
COMPONETS ARE REQUESTED);
SUFFICIENT QUANTITIES TO
CONNECT THE OUTPUT OF THE
DTV MASK FILTER TO THE TEST
Содержание DiamondCD Series
Страница 4: ...MRH 2 888 2463 001 3 6 08 WARNING Disconnect primary power prior to servicing ...
Страница 6: ......
Страница 8: ...viii 888 2463 001 3 6 08 WARNING Disconnect primary power prior to servicing ...
Страница 10: ......
Страница 29: ......
Страница 210: ...7 58 888 2463 001 7 08 03 WARNING Disconnect primary power prior to servicing Section 7 Parts List Diamond Series ...