Chapter 5 Elevator Dedicated Parameters GK600E User Manual
- 58 -
A0-03
Parameter restoration
Range: 0~4
Factory default:
0
0: No operation
1: Clear fault record
When this parameter is set to 1, all fault record of Group U1 w ill be cleared.
2: Restore all parameters to factory default (excluding motor parameters)
3: Restore all parameters to factory default (including motor parameters)
4: Restore all parameters to backup parameters
Group b1 Start/Stop Control
b1-00
Run command
Range: 0~2
Factory default: 1
This parameter sets run command source. Run commands include "RUN, STOP, FWD and
REV", etc. Please keep the default to terminal control if there is no peculiar requirement for lift
application.
0: Control panel control
Control run command through RUN, STOP/RESET and MF keys on control panel (set
multifunction key MF to JOG by L0-00). Refer to Chapter 4 about the operation of control
panel.
1: Terminal control
Control run command via DI terminals. Perform FORWARD and REVERSE by DI terminals.
The control mode is tw o-w ire mode and three-w ire mode programmable. See Group C0 for
details of designation and w iring regulation of DI terminals.
2: Communication control
Master device is able to control run command through built-in RS485 serial communication
interface of drive. Refer to parameters Group H0 and appendix for further information about
programming.
b1-01
Binding of run command
and frequency set
Range: 000 ~ AAA
Factory default:
090
This parameter defines the bundled combination of three run command sources and frequency
set w ith the purpose of facilitating simultaneous sw itching. For example: frequency setting AI1
(ones place of b1-01 is set to 3) bundled w ith control panel control, w hile the frequency setting
X6/DI pulse input (ten's place of b1-01 is set to 6) bundled w ith terminal control. In such a case,
w hen run command is controlled by control panel, frequency setting w ould be AI1, w hile w hen
run command is controlled via terminals, frequency setting w ill be automatically sw itched to
X6/DI pulse input.
Ones place: frequency setting bundled under control panel control