GK600E User Manual
Chapter 5 Elev ator Dedicated Parameters
- 65 -
correctly input motor parameters d0-01~d0-06 before motor tune.
0: No motor auto-tune
1: Static motor auto-tune
Static motor auto-tune applies to the cases w here rotary auto-tune cannot be favorably
performed due to the fact that it is impossible to disengage the motor from its load. After
d0-22 is set to 1 and confirmed, press the key RUN to start static auto-tune. d0-22 w ill be
restored to 0 upon the successful completion of auto-tune. In this w ay, parameters
d0-07~d0-09 are obtained.
2: Rotary motor auto-tune
To perform rotary auto-tune, it is essential to disengage the motor from its load. Auto-tune is
prohibited w hen motor is loaded. After d0-22 is set to 2 and confirmed, press RUN to perform
Rotary auto-tune, upon the completion of w hich, the motor w ould accelerate to a fixed
frequency in the set ramp-up time, maintaining a period of time, and then stop by ramp dow n
according to the set ramp dow n time. In this w ay, the auto-tune comes to an end, and d0-22
w ill be restored to 0. Parameters d0-07~d0-14 have be obtained after the successful
completion of rotary auto-tune. To perform rotary auto-tune, please set appropriate ramp-up
and ramp-dow n time (i.e. Accel/Decel time. If overcurrent or overvoltage fault occurs during
auto-tune, please prolong Accel/Decel time accordingly.)
ATTENTION:
To consider the comfort of lift, GTAKE adopts multi-step V/f control technology rather than
vector control, and therefore motor atuto-tune is not required usually. How ever, if users still
w ould like to have motor auto-tune, please only perform static tune and first b1-00 should be
set to 0 (keypad control). After auto-tune is successfully done, please restore b1-00 to 1
(terminal control).
The motor run contactor must be closed during tuning procedure in order to allow drive output
current to flow into the motor. Either hard-w ire the RUN contactor closed during tuning
procedure, or connects the dedicated output of the drive to the RUN contactor. Please make
sure the motor is in a stationary state before the tuning, or tuning cannot be performed normally.
Control panel displays "TUNE" and RUN indicator light is on during tuning. RUN indicator light
is off upon the completion of tuning. Once tuning fails, the fault code "tUN" shall be displayed.
Group d1 Motor V/f Control Parameters
Set control parameters in Group d1 w hen motor 1 is selected as current load motor on w hich
V/f control is performed.
d1-00
V/f curve setting
Range: 0~8
Factory default: 1
Set the relation betw een output voltage and output frequency of the drive w hen motor is
under V/f control.
0: Linear V/f