Chapter 6 List of Parameters GK600E User Manual
- 86 -
Parameter
Designation
Scope
Factory
default
Attr
30: PLC step completed
31: PLC cycle completed
32: Wobble frequency attains to
upper or low er limit frequency
33: Upper/low er limit of set FREQ
attained
34: Target FREQ attained (set by
C2-29)
35: Run contactor control
35~99: Reserved
C1-04
Y1 output time delay
0.0s~3600.0s
0.0s
△
C1-05
Y2 output time delay
0.0s~3600.0s
0.0s
△
C1-06
Control board relay output
time delay
0.0s~3600.0s
0.0s
△
C1-07
Option board relay output
time delay
0.0s~3600.0s
0.0s
△
C1-08
Enabled state of digital
output
Ones place: Y1
0: Positive logic
1: Negative logic
Tens place: Y2 (same as ones place)
Hundreds place: control board relay
output (same as ones place)
Thousands place: option board relay
output (same as ones place)
0000
×
C1-09
Detected object of FREQ
detection (FDT)
Ones place: FDT1 detected object
0: Speed set value (FREQ after
Accel/Decel)
1: Detected speed value
Tens place: FDT2 detected object
0: Speed set value (FREQ after
Accel/Decel)
1: Detected speed value
00
△
C1-10
FDT1 upper value
0.00Hz~maximum FREQ
50.00Hz
△
C1-11
FDT1 low er value
0.00Hz~maximum FREQ
49.00Hz
△
C1-12
FDT2 upper value
0.00Hz~maximum FREQ
25.00Hz
△
C1-13
FDT2 low er value
0.00Hz~maximum FREQ
24.00Hz
△
C1-14
Detection w idth of FREQ
attained
0.00Hz~maximum FREQ
2.50Hz
△
C1-15
Zero current detection
value
0.0%~50.0%
5.0%
△
C1-16
Zero current detection time
0.01s~50.00s
0.50s
△
Group C2 Analog and Pulse Input