Chapter 3 Installation and Wiring GK600E User Manual
- 24 -
3.5 Terminal Configuration
Fig. 3-10 Terminal configuration
3.6 Main Circuit Terminals and Wiring
WARNING
Only qualified personnel familiar w ith AC motor drives and passenger lift are allow ed to
implement w iring. Failure to comply may result in equipment damage and/or personnel
injury even death.
Wiring should be in strict accordance w ith this manual, otherw ise hazard of electric
shock or equipment damage exists.
Make sure input pow er supply has been completely disconnected before w iring
operation. Failure to comply w ill result in personnel injury even death.
All w iring operations and lines should comply w ith EMC and national and local industrial
safety regulations and/or electrical codes. The conductor diameter should be in
accordance w ith recommendations of this manual. Otherw ise, hazard of equipment
damage, fire, and/or personnel injury exists.
Since leakage current of the drive may exceed 3.5mA, f or safety's sake, the drive and
the motor must be grounded so as to avoid hazard of electric shock.
Be sure to perform w iring in strict accordance w ith the drive terminal marks. Never
connect three-phase pow er supply to output terminals U/T1, V/T2 and W/T3. Failure to
comply w ill result in equipment damage.
Only mount braking resistors at terminals and B2.
When needed, only mount DC reactors at terminals and , and remove the
jumper connected betw een and . Never connect the jumper and DC reactor to
控制回路端子
主回路端子
接地端子
Control circuit terminals
Main circuit terminals
+ 2/B1
+ 1
+ 2
+ 1
+ 2
Grounding terminals