GK600E User Manual
Chapter 5 Elev ator Dedicated Parameters
- 57 -
5.3 Startup Manual
In order to make drive installation and commissioning easier, all the parameters needed for
standard setup are gathered in the
STARTUP
menu. The list of parameters in startup menu of
the lift version follow s:
Group A0: System Parameters
A0-00
Setting of user passw ord
Range: 0~FFFF
Factory default:
0000
Setting of password:
A non-zero four-digital number could be set as a user passw ord by entering this passw ord into
A0-00 and pressing ENT key to confirm once, then reenter and reconfirm it once again w ithin
10 seconds. Once this passw ord has been successfully set, the w ord "P-SEt" w ould be
displayed. The passw ord setting w ill take effect as long as there is no operation on control
panel w ithin 5 minutes, or cutting the pow er off and pow er up again.
Change password:
Access A0-00 after entering the original four-digit passw ord (at this point, A0-00 displays 0000)
and set the new passw ord follow ing the above-noted procedure.
Password clearance:
Access A0-00 after entering the original four-digit passw ord (at this point, A0-00 displays 0000),
enter 0000 tw ice and press ENT key to make confirmation. In this w ay, passw ord is
successfully cleared and the w ord "P-CLr" is displayed.
A0-01
Parameter display
Range: 0~3
Factory default:
0
This parameter sets the display/hide of parameters.
0: Display all parameters (A1-20~A1-21 parameter display/hide is valid)
1: Only display A0-00 and A0-01
2: Only display A0-00, A0-01 and user-defined A1-00~A1-19
3: Only display A0-00, A0-01, and the parameters different from factory defaults.
A0-02
Parameter protection
Range: 0~1
Factory default:
0
0: All parameter programming allow ed
1: Only A0-00 and this parameter programming allow ed
When this parameter is set to 1, all parameters other than A0-00 and A0-02 are not allow ed to
modify. Set A0-02 to 0 before the modification of other parameters.