GK600E User Manual
Chapter 6 List of Parameters
- 89 -
Parameter
Designation
Scope
Factory
default
Attr
11:AI1
12:AI2
13:EAI
14: Reserved
15:DI
16:Communication input percentage
17: Output FREQ before
compensation
18:Output current (relative to motor
rated current)
19:Output torque (direction hinted)
20:Set torque (direction hinted)
21~99: Reserved
C3-03
AO1 offset
-100.0%~100.0%
0.0%
×
C3-04
AO1 gain
-2.000~2.000
1.000
×
C3-05
AO1 filtering time
0.0s~10.0s
0.0s
△
C3-06
EAO offset
-100.0%~100.0%
0.0%
×
C3-07
EAO gain
-2.000~2.000
1.000
×
C3-08
EAO filtering time
0.0s~10.0s
0.0s
△
C3-09
DO maximum output pulse
FREQ
0.1kHz~50.0kHz
50.0kHz
△
C3-10
DO output center point
0: No center point
1: Center point is (C3-09)/2, and the
corresponding parameter value is
positive w hen FREQ is higher than
center point
2: Center point is (C3-09)/2, and the
corresponding parameter value is
positive w hen FREQ is low er than
center point
0
×
C3-11
DO output filtering time
0.00s~10.00s
0.00s
△
Group C4 Automatic Correction of Analog Input
C4-00
Analog correction
0: No correction
1:Correct AI1
2:Correct AI2
3:Correct EAI
0
×
C4-01
Sampling value of AI1
calibration point 1
Range: 0.00V~10.00V
1.00V
◎
C4-02
Input value of AI1
calibration point 1
Range: 0.00V~10.00V
1.00V
×
C4-03
Sampling value of AI1
Range: 0.00V~10.00V
9.00V
◎