F1-17
Emergency speed
Low er limit FREQ ~ upper limit FREQ 5.00 Hz
△
Group F6 Lift dedicated parameters
F6-00
Lift control mode
Ones place: Brake control
0: Disabled
1: Enabled
Tens place: Logic of lift and motor run
direction
0: Positive logic
1: Negative logic
Hundred place : Motor run enable
signal
0: Disabled
1.Enabled
Thousands place:
Leveling compensation
0: Leveling mode 1
1: Leveling mode 2
2: Commissioning mode
0101
×
F6-02
Brake open frequency
0.00Hz ~ 10.00Hz
0.00Hz
△
F6-03
Brake open current
0.0%~200.0%
0.0%
△
F6-05
Magnet time
0.00s~10.00s
0.30s
△
F6-06
Brake open delay
0.00s~10.00s
0.20%
△
F6-07
Smooth start frequency
0.00Hz ~ b0-09
2.00Hz
△
F6-08
Smooth start delay
0.00s~10.00s
0.00s
△
F6-09
Brake close frequency
0.00Hz~10.00Hz
0.20Hz
△
F6-11
Brake w aiting time
0.00s~10.00s
0.40s
△
F6-12
Brake close delay
0.00s~10.00s
0.10s
△
F6-13
Contactor close delay
0.00s~10.00s
0.50s
△
F6-14
Contactor open delay
0.00s~10.00s
0.50s
△
F6-15
Leveling start s-curve time 0.00s~60.00s
0.00s
△
F6-16
Leveling end s-curve time 0.00s~60.00s
0.00s
△
F6-17
Lift-up leveling linear dec
time
0.00s-60.00s
5.00s
△
F6-18
Lift-dow n leveling linear dec
time
0.00s~60.00s
3.00s
△
F6-19
Lift-up slip compensation -400.0%~400.0%
150.0%
△
F6-20
Lift-dow n slip
compensation
-400.0%~400.0%
60.0%
△
F6-22
Leveling frequency
0.00Hz~b0-09
5.00Hz
△
Group H Communication Parameters