GK600E User Manual
Chapter 5 Elev ator Dedicated Parameters
- 55 -
Chapter 5 Elevator Dedicated Parameters
GK600E series are dedicated for open-loop elevator application. The electrical installation,
commissioning and the maintenance of the device should therefore only be carried out by
qualified personnel.
5.1 Standard Wiring
For open loop control, standard w iring of elevator dedicated drives is as show n as below
Fig. 5-1 Elevator standard wiring
M
DC Reactor
Jumper
Braking
Resistor
Motor
Ground
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
Power
Supply
Ground
+
+ 1
2/B1
B2
UPS
1-phase
220VAC
Three-phase
Power Supply
380V-460V
50/60Hz
+24V
PLC
X1
X2
X3
X4
X5
X6
COM
Enable
Run Fwd
Run Rev
Multi-speed sel 1
Multi-speed sel 2
Multi-speed sel 3
RA
RB
RC
+24V
Y1
Y2/DO
COM
+10V
AI1
GND
Relay Output
250V AC/3A
30V DC/3A
Open Collector Output 1
Open Collector Output 2
High-speed Pulse Output
Option Board Interface
CN2
GK600E
Jumper
Analog In Reference
Voltage
POT
OFF
ON
V
I
V
I
485 AI1 AO1
AI2
GND
485 MODBUS
Communication
485+
485-
AO1
GND
GND
Paired
Cable
Shielded
Cable
Analog In
DC: 0~10V/0~20mA
Analog In
DC:-10V~10V
Analog Out
DC:0~10V/0~20mA
Control Panel
-
KM1
KM4
KM1
KM2
KM3
Safety Contacts
X7 (On Option Board)
Emergency Speed
Relay Output
(On Option Board)
250V AC/3A
30V DC/3A
RA
RB
RC
KM2
KM3