Chapter 2 Product Information GK600E User Manual
- 10 -
Basic
functions
Input
terminals
7 digital inputs, one of w hich can be used for high-speed
pulse input, and compatible w ith active open collectors
NPN, PNP and dry contact input.
2 analog inputs, one of w hich is voltage/current
programmable, and the other supports voltage only.
Output
terminals
1 high-speed pulse output, 0~50kHz square w ave signal
output. It can output signals such as frequency setting, or
output frequency, etc.
1 digital output
2 relay output
1 analog output, voltage/current output programmable; can
output signals such as frequency setting, or output
frequency, etc.
Protection
functions
Refer to Chapter 7- Troubleshooting
Environment
Place of
operation
Indoors, no direct sunlight, free from dust, corrosive
gases, flammable gases, oil mist, w ater vapor, w ater drop
or salt, etc.
Altitude
0-2000m. De-rate 1% for every 100m w hen the altitude is
above 1000 meters
Ambient
temperature
-10
℃
-40
℃
. The rated output current should be derated
1% for every 1
℃
w hen the ambient is 40
℃
-50
℃
Relative
humidity
0~95%, no condensation
Vibration
Less than 5.9m/
s
2
(0.6g)
Storage
temperature
-40
℃
~+70
℃
Others
Efficiency at
rated Amps
Rated pow er
7.5kW and below : ≥93%
11~ 30
kW: ≥ 95%
Installation
w all-mounted
IP grade
IP20
Cooling
method
Forced air cooling