48 Steps before and after monitoring
5.3 Switching
off
Always switch off VitaGuard® in the manner described here.
1 Press the <Enter> key and keep this pressed: the message
Press
Esc key
appears.
2 Briefly press the <Esc> key, still keeping the <Enter> key pressed,
and then release both keys.
The switch off command is acknowledged by two short beeps.
Data must be stored before the device finally switches off. For this
reason, VitaGuard® needs about another two seconds after the keys
are released until it switches off completely.
5.4
Summary of steps after monitoring
Switch off VitaGuard® as explained in the previous section.
Carefully detach the ECG electrodes from the patient.
Disconnect the ECG electrodes from the patient cable.
If the procedure concerning stored data has not been clarified dur-
ing your training, then please contact your doctor.