ADL500 • Quick installation guide - Specifications and connection
9
2.1 Dedicated features
ADL510
ADL530
ADL550
Wi-Fi communication
Plug-in for optional Wi-Fi Drive Link module for wireless communication via GF_LifTouch APP (in preparation).
-
Yes
Yes
GF_Liftouch (WebApp)
Fully responsive Web App, compatible with all major browsers on smartphones, tablets and PCs, and with any
operating system (in preparation).
-
Yes
(optional)
Yes
(optional)
GF_DriveLabs (Configurator)
Enhancement of Gefran PC configurator features in the same “family feeling” programming. Includes an inte-
grated real-time oscilloscope and 4 different levels of access (in preparation).
Yes
Yes
Yes
USB PORT
USB port for import/export of inverter files, motor pre-configuration files and selection of language.
-
Yes
Yes
ETHERNET PORT
RJ-45 port for configuration via PC using the Modbus TCP/IP protocol.
Can also be used to connect the inverter to a router for remote control.
Yes
Yes
Yes
GREEN SOLUTIONS AND FEATURES
Regenerative configuration with external AFE200 modules and calculation of the energy saved.
Stand-by feature that deactivates the power section when the system is stopped.
-
-
Yes
Emergency batteries
Emergency battery management
External batteries recharged during braking phase (with system external to the ADL500 drive).
Yes
-
Yes
-
Yes
Yes
Smooth Emergency
To be implemented by adding external systems.
-
Yes
Yes
Optimised SLS control
Sensorless control optimised for asynchronous motors.
Yes
Yes
Yes
Speed control
EFC (Elevator Floor Control) function: separate function for independent management of short floors, landing zone,
re-starting with lift not at floor and automatic deceleration point calculation.
Yes
Yes
Yes
Position control
EPC (Elevator Positioning Control) function: separate function for independent management of direct arrival at the
floor with internal position regulator and saving of floor distances (system autotuning). In preparation.
-
Yes
Yes
Lift sequence
Typical sequence of input/output signals used in civil lift engineering applications such as I/O management, brak-
ing, output contactor and door control.
Yes
Yes
Yes
Parameters in linear unit
Possibility of selecting different engineering units (also with values for the US) for the main movement param-
eters, rpm (fpm) or m/s for speed, m/s², m/s³ (ft/s
2
, ft/s
3
) for cabin acceleration.
Yes
Yes
Yes
Lift mechanical parameters
Mechanical system parameters such as pulley diameter and speed ratio for converting system units and weights,
system for calculating inertia and speed regulation for the desired response.
Yes
Yes
Yes
Ramp generation
Independent configuration of acceleration and deceleration ramp parameters and of the 4 jerk values for maxi-
mum travelling comfort in the lift cabin. Two independent S-shaped ramps, selectable via digital input with 4
independent jerk settings. Dedicated deceleration ramp corresponding to the stop command.
Yes
Yes
Yes
Multiple speeds
8 internally settable speed reference values. Possibility of overwriting at start-up with additional values to ensure
smooth starting.
Yes
Yes
Yes
Pre-torque (load compensation)
Initialisation of the speed regulator by the weight sensor to prevent jerks or bumpy starting.
Yes
Yes
Yes
Increased overload
Overload capacity in line with typical lift application load cycles.
Yes
Yes
Yes
Fan control logic
The fan control logic activates the internal fans according to the temperature.
Yes
Yes
Yes
Emergency single-phase power supply to return to the floor
In emergency conditions a 230 V single-phase supply voltage can be used to return the cabin to the floor by UPS
power supply or batteries with EMS (integrated on ADL5...-....-EMS models).
Yes
Yes
Yes
User-friendly menus
The menus feature lift-specific DISPLAY and motor STARTUP terminology
Yes
Yes
Yes
Saving parameters
Drive parameters can be saved on USB memory.
No
Yes
Yes