38
ADL500 • Quick installation guide - Specifications and connection
7.3.4 +24V supply connection
Note!
For terminal location see section "7.1 Location and identification of terminals and LEDs" on page 26.
Terminal
Description
IN/OUT
1
+24
V
dc
External power supply of the regulation board
IN
2
0
V
dc
external power supply reference
IN
7.3.5 Safety STO connection (SFTY-STO)
Note!
For terminal location see section "7.1 Location and identification of terminals and LEDs" on page 26.
Terminal
Description
IN/OUT
EN+
Enable Safety (+)
IN
EN-
Enable Safety (-)
IN
OK1
Safety OK, Output 1
OUT
OK2
Safety OK, Output 2
OUT
The EN+ , EN-, OK1 and OK2 terminals must be connected as shown in the typical connection diagrams in chapter
"7.9 Connection diagrams" on page 42.
Safety management is integrated
in the firmware.
The Safety must be enabled to enable the drive.
The drive is disabled if the Safety enable command is removed while it is enabled.
To re-enable the drive, re-enable the Safety then remove and re-send both the Enable and Start commands.
7.3.6 Led
Note!
For terminal location see section "7.1 Location and identification of terminals and LEDs" on page 26.
Led
Colour
Meaning
ADL510 ADL530 ADL550
BRK
Yellow
Braking
Yes
Yes
Yes
CNT
Yellow
Contactor closing command status
Yes
Yes
Yes
EN
Green
Enable
Yes
Yes
Yes
LIM
Red
Current limit
Yes
Yes
Yes
AL
Red
Generic alarm
Yes
Yes
Yes
CAN
Green
CAN 1
-
Yes
Yes
S-BY
Yellow
Stand-by
-
-
Yes
UP
Green
Direction up
-
-
Yes
DOWN
Green
Direction down
-
-
Yes
PWR
Green
Power Supply ON
-
-
Yes
Содержание ADL500