8. Use of the optional keypad (KB-ADL500)
This section describes the optional KB-ADL500 programming keypad (cod. S5P11T) and how to use it (display and
programming parameters).
Note !
For the connetion refer to section "7.6 Optional Keypad interface (RJ45 connector)" on page 41.
8.1 Description
→
Drive status indicator LEDs
E
BRK
CNT
EN
ILim
n=0
AL
DISP
ESC
SAVE
CUST
FIND
RST
01 STARTUP WIZARD
02 OPTIMIZATION WIZAR
03 TROUBLESHOOTING
04 DRIVE
←
128 x 64 dot liquid crystal graphic display, with amber backlighting.
→
Membrane keypad
8.1.1 Membrane keypad
This section describes the keys on the membrane keypad and their functions
Symbol
Reference
Description
ESC
Escape
Returns to the higher level menu or submenu. Exits a parameter, a list of parameters, the list of the last 10 parameters and the
FIND function.
Can be used to exit a message that requires use of this.
SAVE
Salva
Saves the parameters directly in the non-volatile memory without having to use PAR 550
Save parameters
FIND
Trova
Enables the function for accessing a parameter using its number. To exit these functions, press the
key.
RST
Reset
Resets alarms, only if the causes have been eliminated.
CUST
Custom
Displays the last 10 parameters that have been modified. To exit these functions, press the
key.
DISP
Display
Displays a list of drive functioning parameters.
E
Enter
Enters the submenu or selected parameter, or selects an operation. It is used when modifying parameters to confirm the new
value that has been set.
Up
Moves the selection up in a menu or list of parameters.
During modification of a parameter, increases the value of the digit under the cursor.
Down
Moves the selection down in a menu or list of parameters.
During modification of a parameter, decreases the value of the digit under the cursor.
Left
Returns to the higher level menu. During modification of a parameter, moves the cursor to the left.
Right
Accesses the submenu or parameter selected. During modification of a parameter, moves the cursor to the right.
8.1.2 Meaning of LEDs
LEDs
Meaning of LEDs
BRK
The LED is lit when the drive has activated the brake release command
CNT
The LED is lit when the drive has activated the close contactors command
EN
The LED is lit during IGBT modulation (drive operating)
ILIM
When this LED is lit the drive has reached a current limit condition. During normal functioning, this LED is off.
N=0
The LED is lit when motor speed is 0.
AL
The LED is lit when the drive signals that an alarm has been triggered