30
ADL500 • Quick installation guide - Specifications and connection
7.3 Regulation section
Note!
All terminal strips are extractable. For electrical properties of analog, digital and relay inputs/outputs
see section A.2 of the Appendix
.
7.3.1 Cable cross-sections
Terminals
Maximum cable cross-section
Recommended stripping
Tightening torque (min)
(mm
2
)
(AWG)
(mm)
(Nm)
T3, T4, SFTY-STO
0.2 ... 2.5 (1 cable)
0.2 ... 0.75 (2 cables)
26 ... 12
26 ... 19
5
0.4
T1, T2, XER, XE
0.2 ... 1.5 (1 cable)
0.2 ... 0.5 (2 cables)
26 ... 16
26 ... 19
5
0.25
7.3.2 I/O and Relays connection
Note!
For terminal location see section "7.1 Location and identification of terminals and LEDs" on page 26.
T3 terminal – Relays Output
Pin
Signal
Description
Command
Associated parameter
ADL510 ADL530 ADL550
50
RO_4O
Relay 4 output (contact N.O., 24
V
dc
)
1416, Dig output 4 src
Yes
Yes
Yes
51
RO_4C
Common Relay 4
DoopOpen
Yes
Yes
Yes
52
RO_3O
Relay 3 output (contact N.O., 24
V
dc
)
1414, Dig output 3 src
Yes
Yes
Yes
53
RO_3C
Common Relay 3
Run Contactor
Yes
Yes
Yes
54
RO_2O
Relay 2 output (contact N.O., 24
V
dc
)
1412, Dig output 2 src
Yes
Yes
Yes
55
RO_2C
Common Relay 2
Brake Contactor
Yes
Yes
Yes
56
RO_1O
Relay 1 output (contact N.O., 24
V
dc
)
1410, Dig output 1 src
Yes
Yes
Yes
57
RO_1C
Common Relay 1
Drive OK
Yes
Yes
Yes
T1 terminal – Digital inputs
Pin
Signal
Description
Command
Associated parameter
ADL510 ADL530 ADL550
1
DI_8
Digital input 8
Contactor feedback
Yes
Yes
Yes
2
DI_7
Digital input 7
Feedback brake
Yes
Yes
Yes
3
DI_6
Digital input 6
Multispeed 2
Yes
Yes
Yes
4
DI_5
Digital input 5
Multispeed 1
Yes
Yes
Yes
5
DI_4
Digital input 4
Multispeed 0
Yes
Yes
Yes
6
DI_3
Digital input 3
Emergency
Yes
Yes
Yes
7
DI_2
Digital input 2
Start reverse
Yes
Yes
Yes
8
DI_1
Digital input 1
Start forward
Yes
Yes
Yes
T4 terminal – Enable / reference digital inputs and +24V
Pin
Signal
Description
Command
Associated parameter
ADL510 ADL530 ADL550
9
EN_HW
Enable digital inputs
Yes
Yes
Yes
10
DI_CM
Common reference digital inputs
Yes
Yes
Yes
11
0V24_OUT
Ground reference output voltage
Yes
Yes
Yes
12
+24V_OUT
+24
V
dc
output voltage power supply
Yes
Yes
Yes
T2 terminal – Analog input and motor PTC
Pin
Signal
Description
Command
Associated parameter
ADL510 ADL530 ADL550
1
MOT-
PTC reference
-
Yes
Yes
2
MOT+
PTC signal
-
Yes
Yes
3
AI_1P
Analog input 1
Yes
Yes
Yes
4
AI_1N
Common reference analog input
Yes
Yes
Yes
T2 terminal shield connection (recommended)
1) remove the front cover (unscrew the 4 M3 screws with a Ph2 Phillips
screwdriver, see section "A.1.1 - Installation" on page 87),
2) attach a spade lug connector to the signal cable shield,
3) loosen the ground screw on the metal frame, insert the fork and then
screw it down.
T4
T2
T1
XER
XE
Содержание ADL500
Страница 95: ......